CAUTION:
To reduce the risk of damage to the equipment when installing HPE CL Eth 1x100Gb
MLX5 PCIe3 or HPE CL Eth 2x50Gb MLX5 PCIe3:
• You must adjust the thermal policy in BIOS setup to a minimum of
Increased Cooling
or
Maximum Cooling
for added thermal protection. See
Server Management menu
.
• Do not exceed 30ºC (86ºF) ambient temperature.
Table 1: PCIe Population
Components
Slot1
Slot2
Slot3
HPE CL BCM 9460-8i
CVPM05 RAID
Controller
Yes
No
No
HPE CL Eth 1x100Gb
MLX5 PCIe3 FIO Card
No
No
Yes
HPE CL Eth 2x50Gb
MLX5 PCIe3 Card
No
No
Yes
HPE CL LSI-9300-8i
SAS HBA Card
Yes
No
No
You must adjust the thermal policy in BIOS setup to a minimum of Increased Cooling or Maximum Cooling for added
thermal protection. See
.
For 10NVMe SFF, PCIe cards are not supported due to location of NVMe risers.
Procedure
.
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Do one of the following:
a. Extend the server from the rack
.
b. Remove the server from the rack
.
.
6.
If a retaining screw is installed, remove the screw and then remove the expansion card.