Important Safety Information
Please reference page 1 for all warnings.
Important Safety Information for Installers
Leave this manual with the end-user and instruct them to retain it for
future reference. Instructions and product updates are also available at
under the Support tab.
Installers must carefully follow the instructions in this manual to prevent
personal injury or property loss. These instructions contain information
critical to the safe installation and operation of the fire pit.
• Instructions are updated as needed. It is the responsibility of the
installers to check for product updates and installation manual
updates at
www.hpcfire.com/ support.html
prior to installation.
• It is the responsibility of the installer to follow:
- The National Fuel Gas Code, ANSI Z223.1/NFPA 54 or International Fuel
Gas Code.
- Natural Gas and Propane Installation Code CSA B149.1 or CSA
B149.2.
- The National Electrical Code, ANSI/NFPA 70. In Canada, Canadian Electrical Code CSA22.1.
- Local codes
•
Control options:
Use of wall switch, optional remote control (#578-C),
automatic shut-off timer or whole house system.
Gas
• Only use the gas/fuel type specified for this fire pit, refer to the label on
the fire pit control box. Never use an alternative fuel to include biofuel,
ethanol, lighter fluid or any other fuel.
• Gas pressure and type should be checked prior to use and installation.
-
Natural Gas Fire Pit:
Supply Pressure: Minimum: 6.0
inches W.C.; Maximum: 7.0 inches W.C.
-
LP Gas:
Supply Pressure: Minimum: 8.0
inches W.C.; Maximum: 11.0 inches W.C.
If pressure is low, this will reduce flame height
on HIGH setting, possibly resulting in little to
no flame variation.