30
Villa Series Installation
Natural gas connection
The Villa Series can be ordered to be connected to LP or natural gas.
A shut off valve should be placed between the house and the oven.
It’s very important to have correct diameter gas lines for desired oven output.
Connect an approved Natural Gas line to the right side of the oven, located on the underside of
the oven hearth plate.
Make sure all the connections are tight and comply with local codes. Turn gas shut off valve on
and check for leaks.
Follow how to start the oven instructions.
Natural Gas needs to be
connected here.
The installation of this appliance must conform with local codes or, in the absence of local codes, with either
the National Fuel code, ANSI Z223.1/NFPA54, National Gas propane Installation code, CSA B149.2.Installation
in Canada must be in accordance with the standard CAN/CGA-B149.2.(Installation code for gas burning
appliances and equipment) and local codes