Install The Villa Series only in a solid surface counter that is able to withstand high temperatures,
like: granite, concrete, or ceramic tile.
Keep combustible materials 12 inches from side of oven’s hearth
Two people or more are necessary for installation of the oven.
oven cannot be set on top of counter( its design needs to have air flow throughout the entire
bottom)
*Minimum opening width has to be 33 1/2 inches
*Maximum opening width has to be 33 3/4 inches
*Support is needed on each side of the counter 1 ½ inches from rough opening (locking tabs from
phalange need to go underneath the counter)
* Oven
cannot be set on top of counter
(its design needs to have air flow throughout the entire bottom)
Cut-out Diagram for Countertop
For flange rough opening cutout
Rough opening 33 1/2”– 33 3/4”
wide
Rough opening 32”deep
Front of counter
Back of counter
This yellow area must stay
open underneath. Do not install
oven on top of counter
Min. countertop depth
34”