M 322
Operator Manual
97
Reversing switch in short-circuit.
➥
Replace the inverter.
Blown fuses
➥
Check and replace.
Rotation control pedal fails to return to the central position
Control spring broken.
➥
Replace the command spring.
Bead breaker pedal and turntable pedal do not return to home position
Control spring broken.
➥
Replace the pedal return spring.
Internal air leakage (open left hand cover panel and locate the leak)
Air leak from bead breaker cock.
➥
Replace the cock.
➥
Replace the bead breaker cylinder.
Air leak from the table top cock.
➥
Replace the turntable cylinder.
➥
Replace the swivel connector.
Bead breaker cylinder lacks force,
fails to break beads and leaks air
Silencer plugged.
➥
Replace the silencer
Cylinder gaskets worn
➥
Replace the gaskets.
➥
Replace the bead breaker cylinder.
Bead breaker cylinder leaks air around the pin
Air seal worn.
➥
Replace the gaskets.
➥
Replace the bead breaker cylinder.
Turntable will not rotate in either direction
Inverter fault.
➥
Replace the inverter.
Turntable will not turn in either direction
Inverter fault.
➥
Replace the inverter.
Belt broken.
➥
Replace the belt.
Gear unit clamped.
➥
Replace the gear unit.
Summary of Contents for M 322
Page 24: ...82 M 322 Operator Manual 1 2 3 R A B C E F G H L M N O P Q 13 D S T...
Page 50: ...108 M 322 Operator Manual 50b 1 ph...
Page 51: ...M 322 Operator Manual 109 DV 3Ph 50c...
Page 52: ...110 M 322 Operator Manual DV 1Ph 50d...
Page 53: ...M 322 Operator Manual 111 12V 50e...
Page 55: ...M 322 Operator Manual 113 STANDARD VERSION...
Page 56: ...114 M 322 Operator Manual VERSION WITH AIR MOTOR...
Page 57: ...M 322 Operator Manual 115 FS VERSION...
Page 58: ...116 M 322 Operator Manual VERSION WITH AIR MOTOR AND FS...