Hardware options installation 61
4.
Remove the access panel (on page
23
).
5.
Remove the PCI riser cage (on page
26
).
6.
Remove the air baffle (on page
27
).
CAUTION:
Any attempt to remove an installed TPM from the system board breaks or disfigures
the TPM security rivet. Upon locating a broken or disfigured rivet on an installed TPM,
administrators should consider the system compromised and take appropriate measures to ensure
the integrity of the system data.
7.
Install the TPM board. Press down on the connector to seat the board.
8.
Install the TPM security rivet by pressing the rivet firmly into the system board.
9.
Install the air baffle ("
Remove the air baffle
" on page
27
).
10.
Install the PCI riser cage.
11.
Install the access panel (on page
24
).
12.
Install the server into the rack ("
Installing the server into the rack
" on page
31
).
13.
Power up the server (on page
22
).