![background image](http://html.mh-extra.com/html/hp/proliant-dl380-g6-server/proliant-dl380-g6-server_user-manual_164730102.webp)
Specifications 102
Rated input current
10 A at 100 VAC
4.9 A at 200 VAC
Rated input power
930 W at 100V AC input
1348 W at 200V AC input
BTUs per hour
3530 at 120V AC input
4600 at 200V to 240V AC input
Power supply output
Rated steady-state power
800 W at 100V AC input
900 W at 120V AC input
1200 W at 200V to 240V AC
input
Maximum peak power
800 W at 100V AC input
900 W at 120V AC input
1200 W at 200V to 240V AC
input
•
HP ProLiant 750 W Power Supply
Specification
Value
Input requirements
Rated input voltage
100 to 120 VAC, 200 to
240 VAC
Rated input frequency
50 Hz to 60 Hz
Rated input current
8.9 A at 100 VAC
4.3 A at 200 VAC
Rated input power
857 W at 100V AC input
824 W at 200V AC input
BTUs per hour
2925 at 100V AC input
2812 at 200V AC input
Power supply output
Rated steady-state power
750 W at 100V to 120V AC input
750 W at 200V to 240V AC input
Maximum peak power
750 W at 100V to 120V AC input
750 W at 200V to 240V AC input
•
HP ProLiant 460 W Power Supply
Specification
Value
Input requirements
Rated input voltage
100 to 120 VAC, 200 to
240 VAC
Rated input frequency
50 Hz to 60 Hz
Rated input current
5.5 A at 100 VAC
2.6 A at 200 VAC
Rated input power
526 W at 100V AC input
505 W at 200V AC input
BTUs per hour
1794 at 100V AC input
1725 at 200V AC input
Power supply output
Summary of Contents for ProLiant DL380 G6 Server
Page 63: ...Cabling 63 Cabling SAS hard drive cabling Optical drive cabling ...
Page 64: ...Cabling 64 BBWC battery cabling ...
Page 85: ...Troubleshooting 85 ...
Page 110: ...Technical support 110 ...