80
HP ProLiant DL380 Generation 3 Server User Guide
−
The BIOS suspends the server for 5 minutes if it detects a cautionary
temperature level. If the cautionary temperature level is still detected
after 5 minutes, the BIOS performs an orderly shutdown and then
restarts. This process repeats until the cautionary temperature level is no
longer detected.
−
The BIOS performs an orderly shutdown if the following minimum
requirements are not met: one working fan in the I/O zone, five working
fans in the processor zone, and one working fan in the power supply
zone.
−
The server performs an immediate shutdown if it detects a critical
temperature level.
IMPORTANT:
An immediate shutdown is a hardware-controlled
function and it overrides any firmware or software actions.
•
In the operating system:
−
With the Health Driver loaded and Thermal Shutdown enabled in RBSU,
the Health Driver performs an orderly shutdown if it detects a cautionary
temperature level. If the server detects a critical temperature level before
the orderly shutdown occurs, the server performs an immediate
shutdown. Additionally, the Health Driver performs an orderly shutdown
if the following minimum requirements are not met: one working fan in
the I/O zone, five working fans in the processor zone, and one working
fan in the power supply zone.
−
With the Health Driver loaded and Thermal Shutdown disabled in
RBSU, the server performs an immediate shutdown if it detects a critical
temperature level.
−
Without Health Driver loaded, the server performs an immediate
shutdown if it detects a critical temperature level.
IMPORTANT:
An immediate shutdown is a hardware-controlled
function and it overrides any firmware or software actions.
HP CONFIDENTIAL
File Name: 303130-3.doc Last Saved On: 7/7/03 1:48 PM
Summary of Contents for ProLiant DL380 G3
Page 8: ......
Page 11: ...Server Component Identification 11 Front Panel LEDs and Buttons HP CONFIDENTIAL ...
Page 13: ...Server Component Identification 13 Rear Panel Components HP CONFIDENTIAL ...
Page 15: ...Server Component Identification 15 Rear Panel LEDs and Buttons HP CONFIDENTIAL ...
Page 32: ...32 HP ProLiant DL380 Generation 3 Server User Guide Identifying Hot Plug Fans HP CONFIDENTIAL ...
Page 36: ......
Page 44: ......
Page 64: ......
Page 128: ......