SHOW IOX STATUS
•
Command:
SHOW IOX STATUS { ALL | <iox_number> {[ - | , ] <iox_number> }}
•
Description:
Displays IO expansion enclosure status information:
◦
Status
◦
Power state of I/O bays
◦
UID state
◦
Diagnostic status
◦
Power subsystem status
◦
Cooling subsystem status
◦
Xbar Fabric status
◦
I/O slots state
◦
Thermal sensor status
•
Access level/Bay level:
OA Administrator, OA Operator, OA User
•
Restrictions:
You must be connected to the monarch OA.
•
Example:
OA-001CC414F34F> show iox status 6
IOX 6:
Health: OK
Power:
Bay 1: On
Bay 2: Off
Unit Identification LED: Off
Diagnostic Status:
Internal Data OK
Redundancy OK
Power Subsystem:
Status: OK
Redundancy State: Redundant
Power Capacity: 4500 Watts DC
Power Available: 4500 Watts DC
Present Power: 247 Watts AC
PS 1: OK
PS 2: OK
Cooling Subsystem:
Status: OK
Fans Good/Wanted/Needed: 4/4/3
Fan 1: 5486 RPM (30%)
Fan 2: 5479 RPM (30%)
Fan 3: 0 RPM (0%)
Fan 4: 5488 RPM (30%)
Xfabric Link Status:
Link 1: OK
106 IOX enclosure management commands