The
test camnet all
command will execute the global CAMNet test after first checking
that there are no partitions active.
•
Access level/Bay level:
All
•
Restrictions:
The
<physical location>
value must be formatted as either an 8–byte hexadecimal
integer, or a long or medium hardware resource path string (short form strings are not
supported).
◦
◦
Must be in the Health Repository viewer.
TEST FABRIC
•
Command:
TEST FABRIC
•
Description:
Performs an active test of the complex interconnect fabric, the CAMNet manageability fabric,
the global clock distribution, and the OA links. This test detects problems resulting from
malfunctioning hardware, missing or broken cables, or from incorrect cabling. Any test failures
results in a series of hardware indictments referencing specific hardware elements encountering
problems. To view the generated indictments, see
“SHOW INDICT” (page 159)
.
NOTE:
TEST FABRIC
cannot be run on an active complex. You must shut down all partitions
before using the
TEST FABRIC
command.
•
Access level/Bay level:
All
•
Restrictions:
Must be in the Health Repository viewer.
TEST CLOCKS
•
Command:
TEST CLOCKS <physical location>
•
Description:
The command verifies the following:
Global clock distribution to ensure that GPSM clock control registers are set appropriately
for the complex type
◦
◦
If there are no partitions active, the test will also actively manipulate clock generators to
ensure that the cabling is correct on multi-enclosure systems.
◦
This test is also run as part of the
test fabric command
, which requires that no
partitions are active.
◦
All clock sources are working
◦
Each blade is receiving both complex global clock signals
•
Access level/Bay level:
All
162
Health Repository commands