The password of the Administrator account does not change.
The Integrated Administrator is restarted after all the changes
are made.
NOTE:
This command removes all groups, users, and other
customization from the memory of the enclosure, and the
information is unrecoverable.
SET SCRIPT MODE [ON |
OFF]
When SCRIPT MODE is on, all prompting and verifications of
entries cease.
If SCRIPT MODE is on, the following commands require a
password argument: ADD USER, SET USER PASSWORD, or
SET PASSWORD.
An enclosure administrator must change the password so that
the user can log in to the system. Default values are used for
any parameters that would normally require user interaction.
All
SHOW EXPERT {MODE}:
Displays the current EXPERT MODE setting for the current
user.
None
SHOW SESSIONS
Displays the connection to each bay and switch if one exists.
Only one user may connect to each bay and switch at a time.
It also shows the users that are currently logged in, their port
number, connect time, and remote system name.
All
SHOW SSHFINGERPRINT
Displays the key fingerprint of the host SSH public key for the
Integrated Administrator. This can be used from the serial
console to validate the identity of the Integrated Administrator
before initializing an SSH connection across a network.
None
SHOW SSHKEY
Displays the contents of the existing Secure Shell authorized
keys file that is being used for enclosure administrator key-
based authentication.
Only enclosure administrators
may execute this command.
DOWNLAOD CONFIG
<url>
Downloads a previously saved configuration file from a specific
IP host.
The file is auto-executed in SCRIPT MODE. The file is not
allowed to change the password of the Administrator account.
Supported protocols are http, ftp, and tftp. Format the URL as
protocol://host/path/file
. If your ftp server does not support
anonymous connections, you can specify a username and
password by replacing the host part in the previous format with
username:password@host.
All
Table 5-9
Functions Exclusive to the Command Line Interface — Enclosure Management Commands
Function
Description
Capability Exclusive to CLI
Enclosure Management Commands
SHOW CONFIG
Displays the script required to recreate the settings of the
enclosure.
Passwords are not included for any user.
All
SHOW ENCLOSURE FAN
[<fan number> | ALL]
Displays the status, redundancy, partner, speed, and part
number for the requested fan.
The command line adds the
fan partner.
SHOW ENCLOSURE
POWERSUPPLY [<power
supply number> | ALL]
Displays the status of the power supply, AC input status,
capacity, input voltage range #1 (measured in Volts), input
voltage range #2 (measured in Volts), input frequency range
The command line adds the
input voltage ranges, input
frequency range, serial
Table 5-8
Functions Exclusive to the Command Line Interface — General and General Management
Commands (continued)
64
Chapter 5 Command Line Interface
ENWW