Page 24

21091-0-0606

MAINTENANCE INSTRUCTIONS

WARNING:

•  Prior to any maintenance operation, it will be necessary to close the gas supply.

•  Only qualified personnel are allowed to operate these appliances without the front cabinet installed.

OPERATION

FREQUENCY

FAULTS TO BE PREVENT-

ED

REMARKS

External cleaning

As required

External dirty

With wet rag or soft cloth. No 

qualified persons required

General cleaning of appliances

As required. It is advisable to 

perform this operation annu-

ally.

Recirculation of suspended 

particles in surrounding air, 

deposits on the appliance

To be performed by qualified 

personnel

Gas leakage control

Only if the equipment has been 

moved or if any gas circuit ele-

ment has been changed.

Gas leakage

Check with soapy water solu-

tion. To be performed by quali-

fied personnel

Cleaning of pilot burner

As required

Clogging of same

To be performed by qualified 

personnel

In case of doubt, please check with our Customer Service Department

Use soft dry cloth to wipe cabinet.

Use compressed air to remove dust from around pilot and main burner.

Use a vacuum cleaner or compressed air to clean cap and air inlet ring.

CLEANING BURNER AND PILOT

Cleaning of the burner and pilot may be performed by gently vacuuming loose particles and dust from the burner ports and clean-

ing the air intake. Clean the pilot burner with compressed air, pipe cleaner or toothbrush. Do not insert any object (pin, drill bit, etc.) 

through pilot orifice. This will destroy the orifice. Any service which requires disconnecting the gas supply line must be performed by 

a qualified service person.

Note:

 It is recommended to shut off pilot in off season.

Summary of Contents for HW075DVN-1

Page 1: ...manual is not followed exactly a re or explosion may result causing property damage personal in jury or loss of life INSTALLER Leave this manual with the appli ance CONSUMER Retain this manual for fu...

Page 2: ...of HouseWarmer Product 10 15 Clearances to Combustibles 10 Interior Preparation and Installation of the Back of the Unit 11 13 Exterior Installation of the Venting 13 14 Interior Installation of the...

Page 3: ...5 5 lbs 53 2 lbs MAX GAS CONSUMPTION 7 500 Btu hr 13 000 Btu hr 18 000 Btu hr TEST POINT PRESSURE NATURAL GAS 3 5 W C PROPANE LP 10 0 W C SAFETY DEVICES Safety valve thermocouple Warning This direct v...

Page 4: ...me room as the heater Installation and repair should be done by a quali ed service person Heater should be inspected before use and at least annually by a quali ed service person More frequent cleanin...

Page 5: ...Installing Agency Installation and replacement of gas piping gas utilization equip ment or accessories and repair and servicing of equipment shall be performed by a quali ed agency The term quali ed a...

Page 6: ...equiredinaccordance with the above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certi ed 3 SIGNAGE A metal or plastic identi cation plate shall be permanently mounted to th...

Page 7: ...supply inlet to building or the combustion air inlet to any other appliance 6 inches 15 cm for appliance 10 000 Btuh 3 kW 9 inches 23 cm for appliances 10 000 Btuh 3 kW and 50 000 Btuh 15 kW 12 inche...

Page 8: ...service agency or the gas supplier These wall furnace models are designed for direct venting through a wall Only venting components approved for these furnaces may be used Mark the venting system hole...

Page 9: ...chamber support Place the air inlet ring around the tube sealing it against the spacer Insert the cap through the rod and tighten rmly using the blind nut and washer Failure to position these parts i...

Page 10: ...in the absence of local codes with the latest edition of the National Fuel Gas Code ANSI Z223 1 2 20 2 5 11 75 WALL THICKNESS MODELS ACCESSORY HW180DV HW130DV HW075DV 8 7 25 6 THREADED ROD 5 8 5 8 5...

Page 11: ...B The center of the gas inlet hole will be located 6 from the oor line Locate the wall bracket template included in your kit and remove the perforated sections Use painters tape to secure the wall bra...

Page 12: ...onto drywall anchors may need to be used Note See instruction sheet to install air inlet gasket ring Wall Mounting Bracket Line up the two 2 screws in the top of the mounting bracket with the holes i...

Page 13: ...tle to no venting showing on the outside of the house See the table on page 10 Combustion Chamber Threaded Rod Install the threaded rod into the combustion chamber See page 10 for cutting rod to prope...

Page 14: ...the air inlet cap by attach ing the washer and brass blind nut to the threaded rod using a screw driver tightening to stabilize the vent kit Air Inlet Cap Slide the air inlet tube over the ue outlet t...

Page 15: ...lectrode wires do not cause a hazard by hanging down Front of Unit Electrode Wires Back of Cabinet Slide the front housing of the unit onto the back of the unit making sure that the temperature contro...

Page 16: ...iping system at test pressures equal to or less than 1 2 psi 3 5 kPa The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing o...

Page 17: ...n f k f k a f a s d f j s a s d f v l m a s a d f a s a d s f a s d f a a s l d f i o i u a s d f j p o a s d l f j a l s d f h j a s d k f j k b a s d a s d f h f Th a k j d k s a k d h f s k d f a s...

Page 18: ...technical department at 877 459 1583 After completion of gas pipe connections all joints must be checked for gas tightness by means of leak detector solution soapy water or an equivalent solution as a...

Page 19: ...a well ventilated room with doors and windows open If loosened tighten gas inlet connection Check gas inlet connection with a soapy water solution to assure no leaks are present Do not regulate primar...

Page 20: ...gas supplier call the re department C Use only your hands to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand do not try to repair it call a quali ed...

Page 21: ...ing through the rectangular open ing on the front cover NOTE It may be necessary to depress for thirty 30 seconds if this is the rst time the heater is connected to the gas supply There may be air in...

Page 22: ...VE TO BURNER HWA32498 HWA32509 HWA32533 21 COMMAND ROD HWA11600 HWA11600 HWA11600 22 AIR INLET PIPE HWA32494 HWA32515 HWA32515 23 FLUE OUTLET PIPE HWA30174 HWA32516 HWA32516 24 COMBUSTION CHAMBER HWA3...

Page 23: ...21091 0 0606 Page 23 PARTS VIEW...

Page 24: ...leakage Check with soapy water solu tion To be performed by quali ed personnel Cleaning of pilot burner As required Clogging of same To be performed by quali ed personnel In case of doubt please chec...

Page 25: ...on MIN for about 10 minutes Burner shuts down while in operation A Gas supply interrupted B Incorrect piping connection A Gas supply re established B Connect piping according to installa tion instruct...

Page 26: ...ber see parts list fails because of defective work manship or material within ten years from the date of purchase Empire will repair or at Empire s option re place the defective combustion chamber Lim...

Page 27: ...21091 0 0606 Page 27 NOTES...