background image

Page 26

21091-0-0606

Parts can be ordered

 only

 through your 

service person or dealer.

 For best results, the 

service person or dealer

 should order parts 

through the distributor. Parts can be shipped directly to the 

service person/dealer

.

All parts listed in the Parts List have a Part Number. When ordering parts, first obtain the Model Number from the name plate on your 

equipment. Then determine the Part Number (

not

 the Index Number) and the Description of each part from the following appropriate 

illustration and list. Be sure to give all this information . . .
Furnace Number  

 

Part Description 

Furnace Serial Number 

 

Part Number  

Type of Gas (Propane or Natural) 
Do not order bolts, screws, washers or nuts. They are standard hardware items and can be purchased at any local hardware store. 
Shipments contingent upon strikes, fires and all causes beyond our control.

HOW TO ORDER REPAIR PARTS

The Company reserves the right of introducing any modification deemed convenient in order to improve the products, or due to any 

manufacture or commercial requirements, without previous notice, provided those modifications are in accordance with the local gas 

code.

This manual will help you obtain efficient, dependable service from your HouseWarmer heater, and enables you to obtain repair parts 

correctly.

HOUSEWARMER HEATING APPLIANCE LIMITED WARRANTY

Limited Ten-Year Warranty

Empire promises to the owner that if the combustion chamber (see parts list) fails because of defective work-

manship or material within ten years from the date of purchase, Empire will repair, or at Empire's option, re-

place the defective combustion chamber.

Limited One-Year Warranty

Should any part fail because of defective workmanship or material within one year from the date of purchase, 

Empire will repair or, at Empire's option, replace the defective part.

Duties Of The Owner

The heating appliance must be installed by a qualified installer and operated in accordance with the written 

instructions furnished with appliance.

Ready access to the appliance for service is the responsibility of the owner.

Travel, diagnostic cost, service labor to repair the defective appliance, and freight charges on warranty parts to 

and from the factory will be the responsibility of the owner.

A bill of sale, cancelled check, or payment record should be kept to verify purchase date and establish warranty 

period.

How to Get Service

Service under this warranty must be obtained by contacting your Empire dealer (See telephone directory or call 

(877) 459-1583, Consumer Relations Department, Empire Comfort Systems, Inc.). Provide the dealer with the 

model number, serial number, type of gas and purchase verification information.

If, after contacting your Empire dealer, service received has not been satisfactory, contact: Consumer Relations 

Department, Empire Comfort Systems, Inc., P.O. Box 529, Belleville, Illinois 62222, or call (877) 459-1583 

for assistance.

Your rights under State Law

This warranty gives you specific legal rights, and you may also have other rights, which vary from state to 

state.

Summary of Contents for HW075DVN-1

Page 1: ...manual is not followed exactly a re or explosion may result causing property damage personal in jury or loss of life INSTALLER Leave this manual with the appli ance CONSUMER Retain this manual for fu...

Page 2: ...of HouseWarmer Product 10 15 Clearances to Combustibles 10 Interior Preparation and Installation of the Back of the Unit 11 13 Exterior Installation of the Venting 13 14 Interior Installation of the...

Page 3: ...5 5 lbs 53 2 lbs MAX GAS CONSUMPTION 7 500 Btu hr 13 000 Btu hr 18 000 Btu hr TEST POINT PRESSURE NATURAL GAS 3 5 W C PROPANE LP 10 0 W C SAFETY DEVICES Safety valve thermocouple Warning This direct v...

Page 4: ...me room as the heater Installation and repair should be done by a quali ed service person Heater should be inspected before use and at least annually by a quali ed service person More frequent cleanin...

Page 5: ...Installing Agency Installation and replacement of gas piping gas utilization equip ment or accessories and repair and servicing of equipment shall be performed by a quali ed agency The term quali ed a...

Page 6: ...equiredinaccordance with the above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certi ed 3 SIGNAGE A metal or plastic identi cation plate shall be permanently mounted to th...

Page 7: ...supply inlet to building or the combustion air inlet to any other appliance 6 inches 15 cm for appliance 10 000 Btuh 3 kW 9 inches 23 cm for appliances 10 000 Btuh 3 kW and 50 000 Btuh 15 kW 12 inche...

Page 8: ...service agency or the gas supplier These wall furnace models are designed for direct venting through a wall Only venting components approved for these furnaces may be used Mark the venting system hole...

Page 9: ...chamber support Place the air inlet ring around the tube sealing it against the spacer Insert the cap through the rod and tighten rmly using the blind nut and washer Failure to position these parts i...

Page 10: ...in the absence of local codes with the latest edition of the National Fuel Gas Code ANSI Z223 1 2 20 2 5 11 75 WALL THICKNESS MODELS ACCESSORY HW180DV HW130DV HW075DV 8 7 25 6 THREADED ROD 5 8 5 8 5...

Page 11: ...B The center of the gas inlet hole will be located 6 from the oor line Locate the wall bracket template included in your kit and remove the perforated sections Use painters tape to secure the wall bra...

Page 12: ...onto drywall anchors may need to be used Note See instruction sheet to install air inlet gasket ring Wall Mounting Bracket Line up the two 2 screws in the top of the mounting bracket with the holes i...

Page 13: ...tle to no venting showing on the outside of the house See the table on page 10 Combustion Chamber Threaded Rod Install the threaded rod into the combustion chamber See page 10 for cutting rod to prope...

Page 14: ...the air inlet cap by attach ing the washer and brass blind nut to the threaded rod using a screw driver tightening to stabilize the vent kit Air Inlet Cap Slide the air inlet tube over the ue outlet t...

Page 15: ...lectrode wires do not cause a hazard by hanging down Front of Unit Electrode Wires Back of Cabinet Slide the front housing of the unit onto the back of the unit making sure that the temperature contro...

Page 16: ...iping system at test pressures equal to or less than 1 2 psi 3 5 kPa The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing o...

Page 17: ...n f k f k a f a s d f j s a s d f v l m a s a d f a s a d s f a s d f a a s l d f i o i u a s d f j p o a s d l f j a l s d f h j a s d k f j k b a s d a s d f h f Th a k j d k s a k d h f s k d f a s...

Page 18: ...technical department at 877 459 1583 After completion of gas pipe connections all joints must be checked for gas tightness by means of leak detector solution soapy water or an equivalent solution as a...

Page 19: ...a well ventilated room with doors and windows open If loosened tighten gas inlet connection Check gas inlet connection with a soapy water solution to assure no leaks are present Do not regulate primar...

Page 20: ...gas supplier call the re department C Use only your hands to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand do not try to repair it call a quali ed...

Page 21: ...ing through the rectangular open ing on the front cover NOTE It may be necessary to depress for thirty 30 seconds if this is the rst time the heater is connected to the gas supply There may be air in...

Page 22: ...VE TO BURNER HWA32498 HWA32509 HWA32533 21 COMMAND ROD HWA11600 HWA11600 HWA11600 22 AIR INLET PIPE HWA32494 HWA32515 HWA32515 23 FLUE OUTLET PIPE HWA30174 HWA32516 HWA32516 24 COMBUSTION CHAMBER HWA3...

Page 23: ...21091 0 0606 Page 23 PARTS VIEW...

Page 24: ...leakage Check with soapy water solu tion To be performed by quali ed personnel Cleaning of pilot burner As required Clogging of same To be performed by quali ed personnel In case of doubt please chec...

Page 25: ...on MIN for about 10 minutes Burner shuts down while in operation A Gas supply interrupted B Incorrect piping connection A Gas supply re established B Connect piping according to installa tion instruct...

Page 26: ...ber see parts list fails because of defective work manship or material within ten years from the date of purchase Empire will repair or at Empire s option re place the defective combustion chamber Lim...

Page 27: ...21091 0 0606 Page 27 NOTES...

Page 28: ...1091 0 0606 HOUSEWARMER is a registered trademark of Empire Comfort Systems Inc Manufactured for Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 PH 877 459 1583 FAX 618 233 7097 or 800...

Reviews: