background image

Page 22

21091-0-0606

PARTS LIST

ITEM

DESCRIPTION

HW075DV

PART NUMBER

HW130DV

PART NUMBER

HW180DV

PART NUMBER

1

GLASS VIEWER

HWA10280

HWA10280

HWA10280

2

VIEWER FRAME

HWA30098

HWA30098

HWA30098

3

VIEWER GASKETS

HWA30096T

HWA30096T

HWA30096T

4

IGNITOR

HWA10453

HWA10453

HWA10453

5

IGNITOR LOCK

HWA12847

HWA12847

HWA12847

6

IGNITOR WIRE

HWA12846

HWA12846

HWA12846

7

PUSHBUTTON

HWA12511

HWA12511

HWA12511

8

CONTROL KNOB

HWA11263I

HWA11263I

HWA11263I

9

THERMOCOUPLE

HWA12855

HWA10704

HWA10704

10

PILOT SPARKER

HWA10712

HWA10712

HWA10712

11

PILOT SPARKER WIRE

HWA12843

HWA12852

HWA12853

12

PILOT UNIT

HWA10706

HWA10706

HWA10706

13

PILOT GASKET

HWA30646F

HWA30646F

HWA30646F

14

PILOT INJECTOR NG (ORIFICE)

HWA10708

HWA10708

HWA10708

14

PILOT INJECTOR LPG (ORIFICE)

HWA10710

HWA10710

HWA10710

15

BURNER INJECTOR NG (ORIFICE)

HWA32535

HWA32542

HWA32543

15

BURNER INJECTOR LPG (ORIFICE)

HWA32544

HWA30122

HWA31177

16

THERMOSTATIC VALVE NG

HWA10692

HWA10692

HWA10692

16

THERMOSTATIC VALVE LPG

HWA10694

HWA10694

HWA10694

17

COMMAND PANEL

HWA10809I

HWA10809I

HWA10923I

18

GROUND WIRE

HWA10455

HWA10455

HWA10455

19

PIPE, VALVE TO PILOT

HWA32497

HWA32508

HWA32532

20

PIPE, VALVE TO BURNER

HWA32498

HWA32509

HWA32533

21

COMMAND ROD

HWA11600

HWA11600

HWA11600

22

AIR INLET PIPE

HWA32494

HWA32515

HWA32515

23

FLUE OUTLET PIPE

HWA30174

HWA32516

HWA32516

24

COMBUSTION CHAMBER

HWA32491P

HWA32514P

HWA32537P

25

AIR INLET RING

HWA32492E

HWA32517E

HWA32517E

26

CAP

HWA32493E

HWA32518E

HWA32518E

27

THREADED ROD

HWA10098

HWA10097

HWA10775

28

BLIND NUT

HWA10113

HWA10113

HWA10113

29

FRONT CABINET

HWA31966EM

HWA32512EM

HWA30828EM

30

BURNER UNIT

HWA32561P

HWA32530P

HWA30868P

31

COMMAND PANEL LOCK

HWA10450

HWA10450

HWA10450

32

NAMEPLATE HOUSEWARMER

HWA12834

HWA12834

HWA12834

33

DISTRIBUTION CHAMBER

HWA32490P

HWA32513P

HWA32536P

34

AIR INLET GASKET

HWA12768

HWA12770

HWA12769

35

FLUE OUTLET GASKET

HWA12767

HWA12769

HWA12769

36

GRILL

HWA30066P

HWA30186P

HWA30061P

37

DEFLECTOR SHIRT

HWA30157

HWA30196

HWA30818

38

DEFLECTOR SHIRT SUPPL.

HWA30158

HWA30158

HWA30158

39

DEFLECTOR, RIGHT SIDE

HWA30152

HWA30152

HWA30824

40

DEFLECTOR, TOP

HWA30154

HWA30193

HWA30800

41

BURNER COVER

HWA32496P

HWA32507P

HWA32557P

42

BURNER COVER GASKET

HWA31384T

HWA31386T

HWA31386T

43

BURNER INJECTOR FITTING

HWA10119

HWA10119

HWA10836

44

CHAMBERS CLAMPS

HWA30159

HWA30159

HWA30864

45

REAR PANEL

HWA31987EM

HWA32528EM

HWA3254EM

46

WALL BRACKET

HWA32443

HWA32444

HWA32445

47

VENTING SYSTEM GASKET

HWA12867

HWA12868

HWA12868

48

SPACER

HWA32499P

HWA32555P

HWA32555P

Summary of Contents for HW075DVN-1

Page 1: ...manual is not followed exactly a re or explosion may result causing property damage personal in jury or loss of life INSTALLER Leave this manual with the appli ance CONSUMER Retain this manual for fu...

Page 2: ...of HouseWarmer Product 10 15 Clearances to Combustibles 10 Interior Preparation and Installation of the Back of the Unit 11 13 Exterior Installation of the Venting 13 14 Interior Installation of the...

Page 3: ...5 5 lbs 53 2 lbs MAX GAS CONSUMPTION 7 500 Btu hr 13 000 Btu hr 18 000 Btu hr TEST POINT PRESSURE NATURAL GAS 3 5 W C PROPANE LP 10 0 W C SAFETY DEVICES Safety valve thermocouple Warning This direct v...

Page 4: ...me room as the heater Installation and repair should be done by a quali ed service person Heater should be inspected before use and at least annually by a quali ed service person More frequent cleanin...

Page 5: ...Installing Agency Installation and replacement of gas piping gas utilization equip ment or accessories and repair and servicing of equipment shall be performed by a quali ed agency The term quali ed a...

Page 6: ...equiredinaccordance with the above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certi ed 3 SIGNAGE A metal or plastic identi cation plate shall be permanently mounted to th...

Page 7: ...supply inlet to building or the combustion air inlet to any other appliance 6 inches 15 cm for appliance 10 000 Btuh 3 kW 9 inches 23 cm for appliances 10 000 Btuh 3 kW and 50 000 Btuh 15 kW 12 inche...

Page 8: ...service agency or the gas supplier These wall furnace models are designed for direct venting through a wall Only venting components approved for these furnaces may be used Mark the venting system hole...

Page 9: ...chamber support Place the air inlet ring around the tube sealing it against the spacer Insert the cap through the rod and tighten rmly using the blind nut and washer Failure to position these parts i...

Page 10: ...in the absence of local codes with the latest edition of the National Fuel Gas Code ANSI Z223 1 2 20 2 5 11 75 WALL THICKNESS MODELS ACCESSORY HW180DV HW130DV HW075DV 8 7 25 6 THREADED ROD 5 8 5 8 5...

Page 11: ...B The center of the gas inlet hole will be located 6 from the oor line Locate the wall bracket template included in your kit and remove the perforated sections Use painters tape to secure the wall bra...

Page 12: ...onto drywall anchors may need to be used Note See instruction sheet to install air inlet gasket ring Wall Mounting Bracket Line up the two 2 screws in the top of the mounting bracket with the holes i...

Page 13: ...tle to no venting showing on the outside of the house See the table on page 10 Combustion Chamber Threaded Rod Install the threaded rod into the combustion chamber See page 10 for cutting rod to prope...

Page 14: ...the air inlet cap by attach ing the washer and brass blind nut to the threaded rod using a screw driver tightening to stabilize the vent kit Air Inlet Cap Slide the air inlet tube over the ue outlet t...

Page 15: ...lectrode wires do not cause a hazard by hanging down Front of Unit Electrode Wires Back of Cabinet Slide the front housing of the unit onto the back of the unit making sure that the temperature contro...

Page 16: ...iping system at test pressures equal to or less than 1 2 psi 3 5 kPa The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing o...

Page 17: ...n f k f k a f a s d f j s a s d f v l m a s a d f a s a d s f a s d f a a s l d f i o i u a s d f j p o a s d l f j a l s d f h j a s d k f j k b a s d a s d f h f Th a k j d k s a k d h f s k d f a s...

Page 18: ...technical department at 877 459 1583 After completion of gas pipe connections all joints must be checked for gas tightness by means of leak detector solution soapy water or an equivalent solution as a...

Page 19: ...a well ventilated room with doors and windows open If loosened tighten gas inlet connection Check gas inlet connection with a soapy water solution to assure no leaks are present Do not regulate primar...

Page 20: ...gas supplier call the re department C Use only your hands to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand do not try to repair it call a quali ed...

Page 21: ...ing through the rectangular open ing on the front cover NOTE It may be necessary to depress for thirty 30 seconds if this is the rst time the heater is connected to the gas supply There may be air in...

Page 22: ...VE TO BURNER HWA32498 HWA32509 HWA32533 21 COMMAND ROD HWA11600 HWA11600 HWA11600 22 AIR INLET PIPE HWA32494 HWA32515 HWA32515 23 FLUE OUTLET PIPE HWA30174 HWA32516 HWA32516 24 COMBUSTION CHAMBER HWA3...

Page 23: ...21091 0 0606 Page 23 PARTS VIEW...

Page 24: ...leakage Check with soapy water solu tion To be performed by quali ed personnel Cleaning of pilot burner As required Clogging of same To be performed by quali ed personnel In case of doubt please chec...

Page 25: ...on MIN for about 10 minutes Burner shuts down while in operation A Gas supply interrupted B Incorrect piping connection A Gas supply re established B Connect piping according to installa tion instruct...

Page 26: ...ber see parts list fails because of defective work manship or material within ten years from the date of purchase Empire will repair or at Empire s option re place the defective combustion chamber Lim...

Page 27: ...21091 0 0606 Page 27 NOTES...

Page 28: ...1091 0 0606 HOUSEWARMER is a registered trademark of Empire Comfort Systems Inc Manufactured for Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 PH 877 459 1583 FAX 618 233 7097 or 800...

Reviews: