ATTENTION INSTALLER: INSTRUCT YOUR CUSTOMER ABOUT THE CORRECT
OPERATION OF THE APPLIANCE BEFORE YOU LEAVE.
Air must be exhausted from pipeline by depressing to pilot setting or by loosening gas inlet connection until you smell gas. Qualified ser-
vice persons must conduct this procedure only for the first time the heater is operated, in a well ventilated room, with doors and windows
open. If loosened, tighten gas inlet connection. Check gas inlet connection with a soapy water solution to assure no leaks are present.
Do not regulate primary air burner. They both have been adjusted according to corresponding gas. If burner produces a permanent bright
yellow flame when igniting or when ignited, call: (877) 459-1583.
Connection
Connect wire from piezo igniter to igniter (arrow). Light the appliance
carefully checking all connections with a soapy water solution to assure
no leaks are present.
Reassemble appliance making sure lower end lids fit into installed
grooves. Place knob in position and push down gently.