Installation

!

 Before operating your new appliance please read this instruction booklet 

carefully. It contains important information for safe use, installation and care 

of the appliance.

!

 Please keep these operating instructions for future reference. Pass them on 

to possible new owners of the appliance.

Positioning

!

 Keep packaging material out of the reach of children. It can become a choking 

or suffocation hazard (see Precautions and tips).

!

 The appliance must be installed by a qualified professional according to the 

instructions provided. Incorrect installation may cause harm to people and 

animals or may damage property.

!

 This unit may be installed and used only in permanently ventilated rooms 

in accordance with current national regulations. The following requirements 

must be observed:

•  The room must be equipped with an air extraction system that expels 

any combustion fumes. This may consist of a hood or an electric fan that 

automatically starts each time the appliance is switched on.

In a chimney stack or branched flue. 

(exclusively for cooking appliances)

Directly to 

the Outside

•  The room must also allow proper air circulation, as air is needed for 

combustion to occur normally. The flow of air must not be less than 2 m

3

/h 

per kW of installed power. 

The air circulation system may take air directly 

from the outside by means of a pipe with an 

inner cross section of  at least 100 cm

2

; the 

opening must not be vulnerable to any type 

of blockages.

The system can also provide the air needed for 

combustion indirectly, i.e. from adjacent rooms 

fitted with air circulation tubes as described 

above. However, these rooms must not be 

communal rooms, bedrooms or rooms that 

may present a fire hazard.

•  Intensive and prolonged use of the appliance may necessitate 

supplemental ventilation, e.g. opening a window or increasing the power 

of the air intake system (if present).

•  Liquid petroleum gas sinks to the floor as it is heavier than air. Therefore, 

rooms containing LPG cylinders must also be equipped with vents to allow 

gas to escape in the event of a leak. As a result LPG cylinders, whether 

partially or completely full, must not be installed or stored in rooms or 

storage areas that are below ground level (cellars, etc.). It is advisable to 

keep only the cylinder being used in the room, positioned so that it is not 

subject to heat produced by external sources (ovens, fireplaces, stoves, 

etc. ) which could raise the temperature of the cylinder above 50°C.

A

Examples of 
ventilation holes 
for comburant air.

Enlarging the ventilation slot

between window and floor.

Adjacent

Room

Room to be

Vented

Fitting the appliance

The following precautions must be taken when installing the hob:

•  Kitchen cabinets adjacent to the appliance and taller than the top of the 

hob must be at least 200 mm from the edge of the hob.

•  Hoods must be installed according to their relative installation instruction 

manuals and at a minimum distance of 650 mm from the hob (see figure).

•  Place the wall cabinets adjacent to the hood at a minimum height of 420 

mm from the hob (see figure).

If the hob is installed beneath a wall cabinet, 

the latter must be situated at a minimum of 700 

mm above the hob.

•  The installation cavity should have the dimensions indicated in the figure.

  Fastening hooks are provided, allowing you to fasten the hob to tops that 

are between 20 and 40 mm thick. To ensure the hob is securely fastened 

to the top, we recommend you use all the hooks provided.

555 mm

55 mm

475 mm

Before the installation remove the grids and burners from the hob and turn it 

upside down, making sure you don’t damage the thermocouples and spark 

plugs.

Apply the seals that come with the 

appliance along the outer edges of 

the hob to prevent any passage of air, 

humidity and water (see Figure).

For proper application make sure the 

surfaces to be sealed are clean, dry and 

free of any grease/oil.

Hook fastening diagram

 

Hooking position for top 

H=20mm

  Hooking position for top 

H=30mm

 

 

Front

 

Hooking position for top 

H=40mm

 

Back

!

 Use the hooks contained in the “accessory pack”.

•  Where the hob is not installed over a built-in oven, a wooden panel must 

be installed as insulation. This must be placed at a minimum distance of 

20 mm from the lower part of the hob.

600mm min.

420mm min.

650mm min.

Summary of Contents for PCN 641 IX/HA RU

Page 1: ...and use 12 Precautions and tips 12 Maintenance and care 13 Troubleshooting 13 1 3 5 6 20 24 24 25 25 Rom n Instruc iuni de utilizare PLITA Sumar Instruc iuni de utilizare 1 Avertiz ri 2 Asisten 5 Des...

Page 2: ...rds can cause accidents Avertiz ri ATEN IE Acestaparat ip r ilesaleaccesibiledevin foarte calde n timpul folosirii Trebuie s fi i aten i i s nu atinge i elementele de nc lzire ndep rta i copiiisub8ani...

Page 3: ...3 8 8 8 8...

Page 4: ...4 8 8...

Page 5: ...N This information is found on the data plate located on the appliance and or on the packaging Asisten Comunica i tipul de anomalie modelul ma inii Mod num rul de serie S N Aceste informa ii se g ses...

Page 6: ...Descrierea aparatului Vedere de ansamblu 1 Gr tare de sprijin pentru RECIPIENTELE DE COACERE 2 ARZ TOARE PE GAZ 3 Selectoare de comand ale ARZ TOARELOR PE GAZ 4 Dispozitiv de aprindere al ARZ TOARELOR...

Page 7: ...7 1 2 3 4 5 1 2 3 5 4...

Page 8: ...vent of a leak As a result LPG cylinders whether partially or completely full must not be installed or stored in rooms or storage areas that are below ground level cellars etc It is advisable to keep...

Page 9: ...ould these safety measures not be observed Gas connection The appliance should be connected to the main gas supply or to a gas cylinder in compliance with current national regulations Before carrying...

Page 10: ...increase this low flame setting using the adjusting screw 5 Oncetheadjustmenthasbeenmade replacethesealsontheby passes using sealing wax or a similar substance If the appliance is connected to liquid...

Page 11: ...res Burner Diameter mm Thermal Power kW p c s 100 75 55 3 00 1 65 1 00 Nomin Reduc 0 70 0 40 0 40 By pass 1 100 mm 39 28 28 Nozzle 1 100 mm Flow g h 86 64 50 Nozzle 1 100 mm Flow l h 132 H3 96 Z 79 6...

Page 12: ...ctions provided in the paragraph on Positioning the appliance These instructions are only valid for the countries whose symbols appear in the manual and on the serial number plate The appliance was de...

Page 13: ...ure that the panstand area is aligned with the burner Models equipped with electrical ignition plugs and safety device require thorough cleaning of the plug end in order to ensure correct operation Ch...

Page 14: ...a Gazele de petrol lichefiate mai grele dec t aerul se depun i stagneaz n partea de jos De aceea nc perile n care se depoziteaz butelii cu GPLtrebuieprev zutecuorificiideaerisiresituate nparteadejos p...

Page 15: ...hnicieni autoriza i a se vedea cap Asisten Produc torul i declin orice responsabilitate dac aceste indica ii nu sunt respectate Conectarea la gaz Conectarea aparatului la butelie sau la re eaua de gaz...

Page 16: ...u dac dispozitivulnufunc ioneaz corectc ndarz toarelesuntpeminim m ri i debitul minimelor manevr nd urubul de reglaj 5 La ncheierea opera iei aplica i ceara de sigiliu sau un nlocuitor pe by pass n ca...

Page 17: ...86 64 50 Duz 1 100 Debit g h mm 132 H3 96 Z 79 6 295 167 100 225 127 76 G31 221 125 75 Specifica iile arz torului i duzei La 15 C i 1013 25 mbar gaze uscate Propan P C S 50 37 MJ Kg Butan P C S 49 47...

Page 18: ...clasa aparatelor ncorporabile din clasa 3 Aparatelepegaznecesit pentruocorect func ionare unregulator de presiune Verifica i ca instalarea acestora s respecte indica iile prev zute n paragraful afere...

Page 19: ...i i i usca i Pune i la loc arz toarele i capacele arz toarelor n mod corect n loca urile respective C ndpune ilalocgr tarele asigura i v c zonapecaresea eaz oalele este aliniat cu arz torul Modelele e...

Page 20: ...20 UA 2 3 100 2 i c a a A 50 200 650 420 700 20 40 555 mm 55 m m 4 7 5 m m H 20mm H 30mm 600mm min 420mm min 650mm min...

Page 21: ...UA 21 H 40mm 20 45 560 560 mm 45 mm 3 50 p p 1 a a epa a L 1 2 1 2 2000...

Page 22: ...22 UA 1 2 7 1 3 4 1 2 3 4 5...

Page 23: ...00 1 100 1 100 mm mm mm mm 28 30 20 35 37 25 45 20 17 25 100 75 55 0 70 0 40 0 40 3 00 1 65 1 00 39 28 28 86 64 50 218 120 73 214 118 71 3 00 1 65 1 00 132 H3 96 Z 79 6 248 157 95 R S A 15 C 1013 25 P...

Page 24: ...24 UA 2 3 1 24 26 16 20 10 14 c R S A 3 2012 19 EU WEEE...

Page 25: ...UA 25 ky 60044 47 01001 4...

Page 26: ...B p e e o a epy 2 3 100 2 A p ep e o ep a o y a pe C e 50 C 200 B 650 P 420 700 20 40 555 mm 55 m m 4 7 5 m m H 20mm H 30mm 600mm min 420mm min 650mm min 26 RU...

Page 27: ...H 40mm B 20 45 560 560 mm 45 mm 3 50 C 1 L 1 2 27 RU...

Page 28: ...1 2 2000 1 C 2 O 7 1 3 4 1 2 3 4 5 a 28 RU...

Page 29: ...7 49 47 37 78 3 R S K p c s 1 100 1 100 1 100 13 6 5 18 1 100 75 55 0 70 0 40 0 40 3 00 1 65 1 00 39 28 28 86 64 50 218 120 73 214 118 71 3 00 1 65 1 00 132 H 96 Z 79 6 286 157 95 p c s 143 105 80 286...

Page 30: ...2 3 1 R S A 24 26 16 20 10 14 3 30 RU...

Page 31: ...2012 19 EU B 50 40 5 40 c 31 RU...

Page 32: ...32 RU...

Page 33: ...2 3 100 2 50 C A 200 650 420 700 20 40 555 mm 55 m m 4 7 5 m m H 20 H 30 H 40 600 420 650 KZ 33...

Page 34: ...20 45 x 560 560 mm 45 mm 3 50 p L 2000 34 KZ...

Page 35: ...1 2 7 3 4 1 P 2 T 3 T 4 5 C O KZ 35...

Page 36: ...7 P C S 37 78 3 1 100 1 100 p c s 28 30 20 35 37 25 45 20 17 25 R S A 100 75 55 0 70 0 40 0 40 3 00 1 65 1 00 39 28 28 86 64 50 218 120 73 214 118 71 3 00 1 65 1 00 132 H 96 Z 79 6 286 157 95 1 p c s...

Page 37: ...2 3 1 R S A 24 26 16 20 10 14 3 WEEE 2002 19 EU KZ 37...

Page 38: ...50 40 5 40 a T 38 KZ...

Page 39: ...KZ 39...

Page 40: ...Indesit Company S p A Viale Aristide Merloni 47 60044 Fabriano AN www hotpoint eu 40 KZ 195144625 00 05 2016 XEROX FABRIANO...

Page 41: ...McGrp Ru McGrp Ru...