73
14. CONTROL BOX
1) Unplug the icemaker.
2) Remove the louver.
3) Remove the two mounting screws, and pull the control box toward you.
4) To refit the control box, push it in horizontally.
Note: After replacing the components inside the control box, connect and tie the wires
properly in their correct position. Especially make sure that the harness is not
pinched between the parts.
[a] FUSE
1) Use a phillips head screwdriver to remove the fuse holder cap, and take out the
fuse.
2) Install the new fuse in the reverse order of the removal procedure.
[b] FUSE HOLDER
1) Disconnect the tab terminal, and remove the nut securing the fuse holder.
2) Install the new fuse holder in the reverse order of the removal procedure.
Screw
Control Box
Relay
Operation Board
Control Board
Control Box
Switching Regulator
Fuse
Fuse Holder
Nut
Board Support