83
2) Open the door, and remove all ice from the
storage bin. Check that the separator is
attached in its correct position as shown.
Otherwise, the solution may splash onto
the ice in the storage bin.
3) Press and hold the cleaning button for 3
seconds. The display flashes the current
mode. For example, the display showing
“run” during the icemaking operation starts
to flash “run”.
4) When the display changes to “cln”, pour the following amount of solution into the
water tank carefully not to overflow it.
KM-40C-HC:
2.0 litres
KM-60C-HC:
2.5 litres
KM-80C-HC:
3.0 litres
5) Rinse the bin liner with clean water to remove any solution spilled in the storage bin.
Then, close the door.
6) Press the cleaning button (or wait for 15 minutes) to start the automated chemical
cleaning.
7) The unit resumes the original state when the cleaning is over.
8) Dilute 11 ml of 5.25% sodium hypochlorite solution with 3 litres of water for sanitising.
9) Repeat the above steps 3) to 7).
[b] PARTS
1) Disconnect the overflow pipe from the water tank. Next, remove the water tank by
pressing down on the snaps on the brackets (L) and (R) and pulling the tank towards
you slightly and pushing it down. Be careful to avoid breakage when handling the
parts.
2) Pull the cube guides (quantity varies depending on model) upward to remove them
from the water tank. They are snapped in place.
3) Prepare 3 litres of 2% citric acid solution for cleaning (descaling).
4) Wash the bin control switch, water tank, float switch, cube guide and overflow pipe
by using a nylon scouring pad, brushes and the solution. In addition to the removed
parts, also wash the bin liner and brackets (L) and (R) with the solution.
Water Tank
Separator