28
E61
Hot gas valve
Opening failure
Replace coil or valve
Hot gas valve relay
Coil circuit open
Replace
Water valve
Opening failure
Clean or replace
Water valve relay
Coil circuit open
Replace
Pump motor
Locked
Replace
Low RPM
Replace motor or control board
E64 Hot gas valve
Closing failure
Replace
Hot gas valve relay
Bad contacts
Replace
E65
Fan motor
Locked
Replace
Starting failure
Replace control board
E66
Pump motor
Locked
Replace
Starting failure
Replace control board
E67 Condenser thermistor
Open circuit
Replace
Short circuit
Replace
Connector disconnected
Reconnect
E69
Water regulator (water-
cooled model only)
Low flow rate
Adjust
Water-cooled condenser
(water-cooled model
only)
Scaled up
Clean
Control board setting
Wrong model code setting
Correct
E71
Water circuit
Low water
Check water tap
Low water pressure
Adjust
Water valve
Closing failure
Clean or replace
Water valve relay
Bad contacts
Replace
Water tank
Disconnected
Reconnect
E73
Float switch
Broken
Replace
Float sticking
Descale
Bad contacts
Replace
E79 Control board thermistor
Open circuit
Replace
Short circuit
Replace
E81 Condenser thermistor
Open circuit
Replace
Short circuit
Replace
Connector disconnected
Reconnect
E82 Icemaking water
thermistor (not provided)
Open circuit
Replace
Short circuit
Replace
Connector disconnected
Reconnect
E90
Water circuit
Low water
Check water tap
Low water pressure
Adjust
Water valve
Clogged filter
Clean
Water tank
Disconnected
Reconnect
Broken
Replace
Separator
Disconnected
Reconnect
Broken
Replace
Pump motor discharge
hose
Disconnected
Reconnect
Spray tube
Disconnected
Reconnect
Drain valve
Closing failure
Replace