19
[5] Reset Button / Enter Button
1) When pressed during the fully automated chemical cleaning, the unit starts the
rinse process and finishes the fully automated chemical cleaning.
2) When pressed with an error code in the display, the unit determines whether to
reset the error.
3) When pressed and held for 3 seconds, the user setting mode starts.
* See “[d] USER SETTINGS” for details.
[c] MODEL CODE SETTING
When the power is supplied, the 7-segment display shows “000” if no model code has
been set.
To set the model code:
-
press the down (ON/OFF) button to change from “_ _ 0” to “_ 13”, “_ 12”, “_ 11”, or
- press the up (cleaning) button to change from “_ _ 0” to “_ _ 1”, “_ _ 2”, “_ _ 3”.
To finish the setting:
- press the enter (reset) button.
[d] USER SETTINGS
The settings listed below are adjustable by the user.
1) Press and hold the reset button for 3 seconds to enter the user setting mode. The
display shows one of the setting codes.
2) Use the up or down button until the display shows the desired setting code. Then,
press the enter button.
3) Use the up or down button to adjust the setting. Then, press the enter button.
4) After finishing the settings, use the up or down button until the display shows “END”.
Then, press the enter button to exit the user setting mode.
Code
Item
Description
Max.
Min.
Step
U.04 Drain frequency
0: No drain
1: Every 1 cycle
2: Every 2 cycles
5: Every 5 cycles
10: Every 10 cycles
20: Every 20 cycles
20
0
–
U.44 Automatic water
cleaning frequency
0: No automatic water cleaning
5: Every 5 cycles
10: Every 10 cycles
15: Every 15 cycles
20: Every 20 cycles
40: Every 40 cycles
60: Every 60 cycles
60