27
n32
LED error
LED temperature fails to rise.
Continue
Replace LED
n33 Fully automated
cleaning error
Water circuit fails to flush properly.
Continue
Turn off power
supply
n70 Low water
Float switch fails to close at lower
float level four times in a row when
checked every minute in fill cycle.
Halt
Automatically reset
in 10 minutes (fill
cycle begins)
n92
High temperature
error 2
Control board thermistor reads set
point or higher temperature for 10
seconds.
Continue
Read set point -
2°C for 10 seconds
n93
Empty chemical
pack
Fully automated chemical cleaning
is repeated more than set number of
times.
Continue
Replace chemical
pack and press
reset button
n99 Maintenance
Time for maintenance.
Continue
Press reset button
Service Diagnosis
Code
Check
Possible Cause
Remedy
E31 LED thermistor
Open circuit
Replace
Short circuit
Replace
Connector disconnected
Reconnect
E40 Control board
EEPROM defective
Replace
E41 Control board
EEPROM defective
Replace
E46
Fan motor
Locked
Replace
Broken fan
Replace fan
Fan motor relay
Coil circuit open
Replace
Water regulator (water-
cooled model only)
Low water
Check water tap
Hot gas valve
Opening failure
Replace coil or valve
Hot gas valve relay
Coil circuit open
Replace
E60
Water valve
Closing failure
Clean or replace
Water valve relay
Bad contacts
Replace
Refrigeration circuit
Gas leak
Repair
Clogged capillary
Replace
Clogged expansion valve
Replace
Compressor
Defective
Replace
Starting failure
Check supply voltage or replace
electrical components
Compressor relay
Coil circuit open
Replace control board
Condenser
Clogged
Clean
Fan motor
Locked
Replace
Broken fan
Replace fan
Fan motor relay
Coil circuit open
Replace
Hot gas valve
Closing failure
Replace
Hot gas valve relay
Bad contacts
Replace
Evaporator thermistor
Disconnected
Reconnect