9
1. Drain
PM
energized
DV
energized
Drain Timer
F/S
open
2. Fill
PM
de-energized
DV
de-energized
WV
energized
2-min Timer
PM
energized
WV
de-energized
PM
continues
DV
energized
30-sec Timer
Legend:
PM
–pump motor
DV
–drain valve
WV
–water valve
Fill Cycle
Harvest
Cycle
F/S
open
PM
de-energized
DV
de-energized
20-min Timer
PM
energized
PM
de-energized
15-min Timer
4. Standby
3. Drain
Drain Timer
F/S
open: No water in water tank
F/S
closed: Water in water tank
[c] HALT CONTROL
1. Drain Process
When the ON/OFF button is pressed, the display flashes “oFF”. After the end of harvest
cycle, every component de-energizes. DV opens in 2 seconds while PM energizes to
drain the water tank. If F/S is open (no water in tank), the drain timer starts counting
down. When the time is up, DV closes while PM de-energizes to start the fill process.
2. Fill Process
WV opens and the 2-minute timer starts counting down. When the time is up, WV closes
while PM energizes and the 30-second timer starts counting down. When the time is up,
PM de-energizes to start the drain process.
3. Drain Process
DV opens in 2 seconds while PM energizes to drain the water tank. If F/S is open (no
water in tank), the drain timer starts counting down. When the time is up, DV closes
while PM and every component de-energize. The display shows “oFF”.
4. Standby Process
To prevent condensation of PM, the unit repeats de-energizing every component for 20
minutes and energizing PM for 15 minutes. When the ON/OFF button is pressed, the
display shows “run” and the fill cycle starts.
* To shut down completely, unplug the unit or turn off the main power supply.
In sanitation mode (Setting 53), the sanitation control starts in 4 hours after the
beginning of halt control.