22
(4) Defrost Completion
1a)
Freezer (auxiliary code P-6 and later)–LEDs 4 (Comp) and 5 (ConFM) are
on. LED 3 (EvapFM on) is off:
When CTh reads 15
°
F (8.3
°
C) above setpoint
or less, cabinet temperature is displayed on DB. Defrost is complete.
1b)
FH1-SSB-HD Freezer–LEDs 4 (Comp and ConFM) and 5 (CPH and DrH
(auxiliary code Q-5 and later)) are on. LED 3 (EvapFM on) is off:
When
CTh reads 15
°
F (8.3
°
C) above setpoint or less, cabinet temperature is
displayed on DB. Defrost is complete.
Legend:
CB
–control board;
Comp
–compressor;
ConFM
–condenser fan motor;
CordH
–cord
heater;
CPH
–condensate pan heater;
CTh
–cabinet thermistor;
DB
–display board;
DctH
–duct heater;
DH
–defrost heater;
DrH
–drain heater;
DT
–defrost timer;
DTh
–defrost thermistor;
EvapFM
–evaporator fan motor;
MH
–mullion heater;
PH
–perimeter heater