54
PROBLEM
POSSIBLE CAUSE
REMEDY
c)
Gear Motor
Protector (Circuit
Breaker)
1.
Tripped
1.
Find out the cause,
get rid of it, and press
Reset Button on
Circuit Breaker.
d) Gear Motor Relay
1.
Coil winding opened. 1.
Replace.
2.
Bad contacts.
2.
Check for continuity
and replace.
e) Control Timer
(Printed Circuit
Board)
1.
Broken.
1.
Replace.
f)
Gear Motor Protect
Relay
1.
Coil winding opened. 1.
Replace.
2.
Bad contacts.
2.
Check for continuity
and replace.
[4] Gear Motor starts,
but Compressor (for
Solenoid Valves) will
not start (open) or
operates (opens)
intermittently
a) Pressure Switch
[Except F-2000MLF]
1.
Dirty Air Filter or
Condenser.
1.
Clean.
2.
Ambient or
condenser water
temperature too
warm.
2.
Get cooler.
3.
Condenser water
pressure too low or
off. (Water-cooled
model only)
3.
Check and get
recommended
pressure.
4.
Water Regulating
Valve set too high.
(Water-cooled model
only)
4.
Adjust it lower.
5.
Fan not rotating.
5.
See "3. [1] a) Fan
Motor."
6.
Refrigerant
overcharged.
6.
Recharge.
7.
Refrigerant line or
components
plugged.
7.
Clean and replace
drier.
8.
Bad contacts.
8.
Check for continuity
and replace.
9.
Loose connections.
9.
Tighten.
b) X2 Relay on Control
Timer
1.
Bad contacts.
1.
Replace.Check for
continuity and replace.
2.
Coil winding opened. 2.
Replace Timer.
c)
Starter [Except three
phase model and
F-2000MLF]
1.
Bad contacts.
1.
Check for continuity
and replace.
2.
Coil winding opened. 2.
Replace.
3.
Loose Connections.
3.
Tighten.
d) Start Capacitor or
Run Capacitor
[Except three phase
model and
f-2000MLF]
1.
Defective.
1.
Replace.
Summary of Contents for F-2000MLF
Page 14: ...14 2 CONDENSER UNIT URC 20F...
Page 16: ...16 II GENERAL INFORMATION 1 CONSTRUCTION F 2000MLF C...
Page 17: ...17 F 2000MRF3 C F 2000MRF C...
Page 18: ...18 F 2000MWF C...
Page 20: ...20 F 2000MWF F 2000MRF C...
Page 21: ...21 F 2000MLF C...
Page 22: ...22 III TECHNICAL INFORMATION 1 WATER CIRCUIT AND REFRIGERATION CIRCUIT F 2000MLF C...
Page 23: ...23 F 2000MRF3 C...
Page 24: ...24 F 2000MWF C...
Page 25: ...25 2 WIRING DIAGRAMS F 2000MLF C...
Page 26: ...26 F 2000MRF3 C...
Page 27: ...27 F 2000MWF C...
Page 28: ...28 F 2000MRF C...
Page 30: ...30 b When Reservoir has been filled Gear Motor starts immediately...
Page 33: ...33 e Low Water Except Water cooled Model where Compressor will operate intermittently...
Page 39: ...39...
Page 69: ...69...