44
F-2000MRF3
APPROXIMATE
Ambient
Water Temp. (F)
ICE PRODUCTION
Temp. (F)
PER 24 HR.
70
2010
(912)
1950
(845)
1895
(860)
80
1845
(837)
1795
(814)
1750
(794)
90
1700
(771)
1695
(769)
1610
(730)
lbs./DAY ( kg/day)
100
1570
(712)
1525
(692)
1410
(640)
APPROXIMATE ELECTRIC
70
2850
--
2850
--
2855
--
CONSUMPTION
80
2855
--
2860
--
2860
--
90
2865
--
2865
--
2875
--
watts
100
2890
--
2890
--
2910
--
APPROXIMATE WATER
70
241
(912)
234
(845)
228
(860)
CONSUMPTION PER 24 HR.
80
222
(837)
216
(814)
210
(794)
90
204
(771)
203
(769)
194
(730)
gal. / day (l/day)
100
188
(712)
183
(692)
169
(640)
EVAPORATOR OUTLET TEMP.
70
14
(-10)
14
(-10)
14
(-10)
°F (°C)
80
14
(-10)
14
(-10)
14
(-10)
90
14
(-10)
14
(-10)
16
(-9)
100
16
(-9)
16
(-9)
16
(-9)
HEAD PRESSURE
70
219
(15.4)
219
(15.4)
219
(15.4)
80
230
(16.2)
230
(16.2)
230
(16.2)
90
241
(16.9)
241
(16.9)
241
(16.9)
PSIG (kg/sq.cmG)
100
271
(19.0)
271
(19.0)
271
(19.0)
SUCTION PRESSURE
70
25
(1.8)
25
(1.8)
25
(1.8)
PSIG (kg/sq.cmG)
80
26
(1.8)
26
(1.8)
26
(1.8)
90
27
(1.9)
27
(1.9)
27
(1.9)
100
29
(2.0)
29
(2.0)
29
(2.0)
CONDENSER VOLUME
214 in
3
HEAT OF REJECTION FROM CONDENSER
16890 BTU/h (AT 90°F /WT 70°F)
HEAT OF REJECTION FROM COMPRESSOR
2860 BTU/h (AT 90°F /WT 70°F)
Note: The data without *marks should be used for reference.
We reserve the right to make changes in specifications and design without prior notice.
50
70
90
Summary of Contents for F-2000MLF
Page 14: ...14 2 CONDENSER UNIT URC 20F...
Page 16: ...16 II GENERAL INFORMATION 1 CONSTRUCTION F 2000MLF C...
Page 17: ...17 F 2000MRF3 C F 2000MRF C...
Page 18: ...18 F 2000MWF C...
Page 20: ...20 F 2000MWF F 2000MRF C...
Page 21: ...21 F 2000MLF C...
Page 22: ...22 III TECHNICAL INFORMATION 1 WATER CIRCUIT AND REFRIGERATION CIRCUIT F 2000MLF C...
Page 23: ...23 F 2000MRF3 C...
Page 24: ...24 F 2000MWF C...
Page 25: ...25 2 WIRING DIAGRAMS F 2000MLF C...
Page 26: ...26 F 2000MRF3 C...
Page 27: ...27 F 2000MWF C...
Page 28: ...28 F 2000MRF C...
Page 30: ...30 b When Reservoir has been filled Gear Motor starts immediately...
Page 33: ...33 e Low Water Except Water cooled Model where Compressor will operate intermittently...
Page 39: ...39...
Page 69: ...69...