45
F-2000MRF3-C
APPROXIMATE
Ambient
Water Temp. (F)
ICE PRODUCTION
Temp. (F)
PER 24 HR.
70
1725
(782)
1685
(764)
1650
(748)
80
1615
(733)
1580
(717)
1545
(701)
90
1515
(687)
1525
(692)
1450
(658)
lbs./DAY ( kg/day)
100
1420
(644)
1390
(631)
1275
(578)
APPROXIMATE ELECTRIC
70
2970
--
2975
--
2980
--
CONSUMPTION
80
2980
--
2985
--
2990
--
90
2995
--
3000
--
3040
--
watts
100
3080
--
3125
--
3165
--
APPROXIMATE WATER
70
207
(782)
202
(764)
198
(748)
CONSUMPTION PER 24 HR.
80
194
(733)
190
(717)
186
(701)
90
182
(687)
183
(692)
174
(658)
gal. / day (l/day)
100
170
(644)
167
(631)
153
(578)
EVAPORATOR OUTLET TEMP
70
12
(-11)
12
(-11)
14
(-10)
°F (°C)
80
14
(-10)
14
(-10)
14
(-10)
90
14
(-10)
14
(-10)
14
(-10)
100
14
(-10)
14
(-10)
14
(-10)
HEAD PRESSURE
70
222
(15.6)
222
(15.6)
222
(15.6)
80
225
(15.8)
225
(15.8)
225
(15.8)
90
228
(16.0)
228
(16.0)
228
(16.0)
PSIG (kg/sq.cmG)
100
262
(18.4)
262
(18.4)
262
(18.4)
SUCTION PRESSURE
70
25
(1.7)
25
(1.7)
25
(1.7)
PSIG (kg/sq.cmG)
80
25
(1.8)
25
(1.8)
25
(1.8)
90
26
(1.8)
26
(1.8)
26
(1.8)
100
29
(2.0)
29
(2.0)
29
(2.0)
CONDENSER VOLUME
214 cu in
HEAT OF REJECTION FROM CONDENSER16750 BTU/h (AT 90°F /WT 70°F)
HEAT OF REJECTION FROM COMPRESSO3000 BTU/h (AT 90°F /WT 70°F)
Note: The data without *marks should be used for reference.
We reserve the right to make changes in specifications and design without prior notice.
50
70
90
Summary of Contents for F-2000MLF
Page 14: ...14 2 CONDENSER UNIT URC 20F...
Page 16: ...16 II GENERAL INFORMATION 1 CONSTRUCTION F 2000MLF C...
Page 17: ...17 F 2000MRF3 C F 2000MRF C...
Page 18: ...18 F 2000MWF C...
Page 20: ...20 F 2000MWF F 2000MRF C...
Page 21: ...21 F 2000MLF C...
Page 22: ...22 III TECHNICAL INFORMATION 1 WATER CIRCUIT AND REFRIGERATION CIRCUIT F 2000MLF C...
Page 23: ...23 F 2000MRF3 C...
Page 24: ...24 F 2000MWF C...
Page 25: ...25 2 WIRING DIAGRAMS F 2000MLF C...
Page 26: ...26 F 2000MRF3 C...
Page 27: ...27 F 2000MWF C...
Page 28: ...28 F 2000MRF C...
Page 30: ...30 b When Reservoir has been filled Gear Motor starts immediately...
Page 33: ...33 e Low Water Except Water cooled Model where Compressor will operate intermittently...
Page 39: ...39...
Page 69: ...69...