![Hoshizaki DBF-AS65WE-T Instruction Manual Download Page 29](http://html1.mh-extra.com/html/hoshizaki/dbf-as65we-t/dbf-as65we-t_instruction-manual_2165449029.webp)
27
ENGLISH
V. OTHER INFORMATION
1. PREPARING THE DISPENSER FOR LONG STORAGE
WARNING
When shutting down the dispenser for more than a week, unplug the unit.
1) Drain the water tank according to “II. 9. [b] DRAINING WATER TANK”.
2) Carry out the following maintenance procedures to clean and drain the beer circuit and to keep the unit clean:
III. 5. CLEANING BEER CIRCUIT WITH SPONGE
6. DISASSEMBLY AND CLEANING OF BEER TAP
7. KEG COUPLER
8. EXTERIOR
9. AIR FILTER
3) When restarting the unit, follow the procedures below:
II. 1. CLEANING BEER CIRCUIT
2. FILLING WATER TANK
3. CHECKS BEFORE OPERATION
4. START UP
5. SETTING LIQUID AND FOAM AMOUNTS
6. DISPENSING
7. SOLD OUT SENSOR
8. END OF DISPENSING OPERATION
2. BEFORE CALLING FOR SERVICE
If the dispenser does not work properly, check the following table before calling for service. If the problem still exists, turn off the
power switch (earth leakage breaker) and contact your dealer/supplier.
Do not attempt to repair the unit by yourself. Only qualified personnel may repair the unit.
Problem
Possible Cause
Remedy
Unit will not
start.
The unit is unplugged.
Plug in.
The fuse is blown out.
Contact your dealer/supplier.
Power failure.
Wait until power is resumed.
Beer is not
cold.
No ice in the water tank.
Wait until ice is produced.
Less than 8 to 13 hours after the power
switch (earth leakage breaker) is turned on.
Ice production takes 8 to 13 hours depending on ambient and
water temperatures. Wait for 8 to 13 hours before dispensing
beer.
Ambient temperature is above 30°C.
Ventilate with a fan to lower ambient temperature.
No cooling water in the water tank.
Fill the water tank. See "II. 2. FILLING WATER TANK”.
The air inlet or outlet is blocked or not clean.
Clean or unblock. See "III. 9. AIR FILTER".
No beer is
dispensed.
The beer keg is empty.
Replace with a new keg. See "II. 3. [d] REPLACING BEER
KEG".
The CO2 gas cylinder is empty.
Replace with a new cylinder. See "II. 3. [b] REPLACING CO2
GAS CYLINDER".
The main valve of CO2 gas cylinder is closed. Open.
The regulator is set to "0".
Adjust the regulator to a proper pressure. See "II. 3. [b]
REPLACING CO2 GAS CYLINDER".
The keg coupler is not attached to the beer
keg correctly.
Check and correct. See "II. 3. [d] REPLACING BEER KEG".
The keg coupler handle is closed.
Open the beer circuit. See "II. 3. [d] REPLACING BEER KEG".
Beer cloggs the beer tap and the lever cannot
move smoothly.
Disassemble and clean the beer tap. See "III. 6.
DISASSEMBLY AND CLEANING OF BEER TAP”.