8) Turn the keg coupler counterclockwise to remove it from the beer keg.
9) Remove the quick beer hose joint from the keg coupler, and put only one cleaning
sponge (accessory) into the joint.
NOTICE
Use of more than one cleaning sponge or a non-accessory sponge can cause
clogging of the beer circuit. In such case, contact your dealer/supplier.
10) Attach the quick beer hose joint to the keg coupler.
11) Wash the cleaning tank thoroughly and fill it with tap water.
Note: If the cleaning tank is not clean, the beer circuit will be contaminated.
12) Turn the keg coupler clockwise to attach it to the cleaning tank.
Note: Wash the joint between the keg coupler and cleaning tank if it is not clean.
13) Open the main valve of the CO2 gas cylinder by turning it counterclockwise a few
times.
14) Turn the regulator adjust dial to set the pressure to “0.15” (MPa).
15) Open the beer circuit.
Rotary type: Turn the keg coupler handle clockwise until it stops.
Vertical type: Push down the keg coupler handle until it locks in place.
Note: If the cleaning tank is provided with a siphon tube, lay the cleaning tank with the ferrule at the top. If not, lay the
cleaning tank with the ferrule at the bottom.
16) Wait until the cleaning sponge and water come out of the liquid nozzle.
17) Turn the regulator adjust dial to set the pressure to “0” (MPa).
18) Close the main valve of the CO2 gas cylinder by turning it clockwise.
19) Check that CO2 gas stops coming out of the nozzle.
20) Close the beer circuit.
Rotary type: Turn the keg coupler handle counterclockwise until it stops.
Vertical type: Unlock and lift the keg coupler handle all the way up.
Keg Coupler
Cleaning Sponge
Quick Beer Hose Joint
Rotary Type
Vertical Type
Keg Coupler Handle
Rotary Type
Vertical Type
Siphon Tube
Provided
Not provided
Keg Coupler Handle
Rotary Type
Vertical Type
Rotary Type
Vertical Type