10
ENGLISH
[c] CHECKS AFTER CONNECTIONS
1) Wash the cleaning tank thoroughly and fill it with tap water.
Note: If the cleaning tank is not clean, the beer circuit will be contaminated.
2) Turn the keg coupler clockwise to attach it to the cleaning tank.
Note: Wash the joint between the keg coupler and cleaning tank if it is not clean.
3) Lift up and remove the platform.
4) Place a bucket on the drain pan to receive cleaning water.
5) Check that the beer tap lever is in the closed (normal) position. Open the main
valve of the CO2 gas cylinder by turning it counterclockwise a few times.
6) Turn the regulator adjust dial to set the pressure to “0.15” (MPa).
7) Open the beer circuit.
Rotary type: Turn the keg coupler handle clockwise until it stops.
Vertical type: Push down the keg coupler handle until it locks in place.
Note: If the cleaning tank is provided with a siphon tube, lay the cleaning tank with the ferrule at the top. If not, lay the
cleaning tank with the ferrule at the bottom.
8) Pull the beer tap lever toward you to pour water out of the liquid nozzle.
9) Check the CO2 gas circuit for gas leaks. If it is leaking, correct the hose connections.
10) Check the beer circuit for water leaks. If it is leaking, correct the hose connections.
11) Keep the beer tap lever in the open position and
turn the regulator adjust dial to set the pressure to “0”
(MPa).
12) Close the main valve of the CO2 gas cylinder by
turning it clockwise.
13) When CO2 gas stops coming out of the nozzle,
push the beer tap lever back to the closed position.
8. CHECKS AFTER INSTALLATION
1) Fill the water tank with the specified water. See “II. 2. FILLING WATER TANK”.
2) Flush the beer circuit and check for water leaks. See “III. 2. BEER CIRCUIT”.
3) Check for proper power supply voltage.
4) Plug in the unit.
* Check that the refrigeration unit and agitator motor start.
(In low temperature conditions, the condenser fan motor may not start until the condenser temperature goes up.)
Keg Coupler Handle
Rotary Type
Vertical Type
Siphon Tube
Provided
Not provided
Bucket
Open Position
CO2 Gas Cylinder
Close
Lever
Closed Position
Lever
Closed Position
CO2 Gas Cylinder
Open
Rotary Type
Vertical Type