15
Electrolyte Circulation System
7145240031 V1.1 (01.2013)
Step 5: Install current sensor
The current sensor detects whether the battery is in charge or discharge mode. The pump works only during
battery charging mode. The inductive sensor comes with a plastic housing. The sensor should be attached to
the negative battery connection cable (refer to Figure 15). This is typically the cable which goes to the charging
device. Use the provided wire straps for attachment.
Note:
• The arrow printed on the current sensor must show towards the charging device (refer to Figure 16).
• The label “This side high sensibility / sensitivity” typically faces towards the battery cable.
Figure 15: Attachment of the current sensor
Figure 16: Arrangement of current sensor
Summary of Contents for Electrolyte Circulation System