11
Electrolyte Circulation System
7145240031 V1.1 (01.2013)
1. Open the battery service holes by pulling the little green plugs which are placed on the battery cell lids (refer
to Figure 7). Keep the green plugs for potential later usage.
Figure 7: Service hole
2. Insert the black rubber part into the service hole of the cell lid (refer to Figure 8).
3. Insert delivered hard plastic air tubes (one into each battery cell). Refer also to Figure 9).
Note:
This tube needs to be pushed through the tiny plastic funnel located on top of an empty gauntlet of
the positive tubular plate right underneath the battery service hole.
The hard plastic tube comes with a length which is compatible to the corresponding battery cell.
When finished the head of the air tube is located 1 to 2 cm beneath the end of the electrode plate sets
(refer also to Figure 6).
4. Mount the plastic T-junctions on top of the hard plastic tubes.
Figure 8: T-junction and rubber insert
Figure 9: Hard platic tube