Main Tab
Start > Settings > Control Panel > Scanner > Main tab
Parameter
Function
Port
Default: Port 1 COM3 is enabled. Port 2 is disabled.COM1 ScrCtl and COM3 ScrCtl are used to ena-
ble the
function.
Power Port 1 while
asleep
When Power Port 1 while asleep is checked, whichever serial port is enabled as Port 1 will remain
powered while the device is in Suspend, at the cost of reduced battery life. This allows a tethered
scanner to wake the device by pressing the trigger on the tethered scanner.
Send Key Messages
(WEDGE)
Default: Enabled. If “Send Key Messages (WEDGE)” is checked, the Scanner Driver is in “Key Mes-
sage” (also known as “character”) mode which sends the bar codes to the application with the focus
as keystrokes. All data scanned is converted to keystrokes and sent to the active window.
If “Send Key Messages (WEDGE)” is not checked, the Scanner Driver is in “Block” mode which buff-
ers the data that can be read by an application from the WDG: device through the OS or APIs. Note
that this latter method is significantly faster than using “Wedge”.
Even if Send Key Messages is enabled (“key mode”), the data is still available using the scanner
APIs (“block mode”). If two or more applications are reading the data in Block mode, ClearBuf must
be set to Off so data is not erased when read. Please refer to the CE API Programming Guide for
details on scanner APIs.
Enable Internal
Scanner Sound
Default: Enabled.
Functionality of the internal scanner driver engine includes audible tones on good scan (at the max-
imum db supported by the speaker) and failed scan. Disable this parameter when good scan/bad
scan sounds are to be handled by alternate means e.g., application-controlled sound files.
Rejected bar codes generate a bad scan beep. In some cases, the receipt of data from the scanner
triggers a good scan beep from an external scanner, and then the rejection of scanned bar code data
by the processing causes a bad scan beep from the VX3Plus on the same data.
3-119
Summary of Contents for VX3Plus
Page 1: ...VX3Plus Vehicle Mount Computer Microsoft Windows CE 5 Operating System Reference Guide ...
Page 14: ...xii ...
Page 18: ...Back 1 RAM Ball 2 Power Connector 3 Strain Relief Clamp 1 4 ...
Page 20: ...1 6 ...
Page 21: ...Chapter 2 Hardware System Hardware 2 1 ...
Page 129: ...3 89 ...
Page 130: ...3 90 ...
Page 149: ...Enter user name password and domain to be used when logging into network resources 3 109 ...
Page 155: ...3 115 ...
Page 180: ...Hat Encoding 3 140 ...
Page 181: ...3 141 ...
Page 190: ...3 150 ...
Page 220: ...4 30 ...
Page 270: ...5 50 ...
Page 280: ...7 4 ...