SV2 Series Safety Shut-off Valves
223
V2F, V2V
SV2 SERIES SAFETY SHUT-OFF VALVES USER MANUAL
Address
Type
Valve
Model
Intelligence
Levels
Description
Data
Type
Content
Dec
Hex
177
B1
Alarms
All
Standard
Cycle count of 7th previous fault
U16
Upper 2 bytes
178
B2
U16
Lower 2 bytes
179
B3
Fault code of 8th previous fault
U16
Number
180
B4
Time stamp of 8th previous fault
U16
Upper 2 bytes
181
B5
U16
Lower 2 bytes
182
B6
Cycle count of 8th previous fault
U16
Upper 2 bytes
183
B7
U16
Lower 2 bytes
184
B8
Fault code of 9th previous fault
U16
Number
185
B9
Time stamp of 9th previous fault
U16
Upper 2 bytes
186
BA
U16
Lower 2 bytes
187
BB
Cycle count of 9th previous fault
U16
Upper 2 bytes
188
BC
U16
Lower 2 bytes
189
BD
Fault code of 10th previous fault
U16
Number
190
BE
Time stamp of 10th previous fault
U16
Upper 2 bytes
191
BF
U16
Lower 2 bytes
192
C0
Cycle count of 10th previous fault
U16
Upper 2 bytes
193
C1
U16
Lower 2 bytes
194
C2
Fault code of 11th previous fault
U16
Number
195
C3
Time stamp of 1th previous fault
U16
Upper 2 bytes
196
C4
U16
Lower 2 bytes
197
C5
Cycle count of 11th previous fault
U16
Upper 2 bytes
198
C6
U16
Lower 2 bytes
199
C7
Fault code of 12th previous fault
U16
Number
200
C8
Time stamp of 12th previous fault
U16
Upper 2 bytes
201
C9
U16
Lower 2 bytes
202
CA
Cycle count of 12thprevious fault
U16
Upper 2 bytes
203
CB
U16
Lower 2 bytes
204
CC
Fault code of 13th previous fault
U16
Number
205
CD
Time stamp of 13th previous fault
U16
Upper 2 bytes
206
CE
U16
Lower 2 bytes
207
CF
Cycle count of 13th previous fault
U16
Upper 2 bytes
208
D0
U16
Lower 2 bytes
209
D1
Fault code of 14th previous fault
U16
Number
210
D2
Time stamp of 14th previous fault
U16
Upper 2 bytes
211
D3
U16
Lower 2 bytes
212
D4
Cycle count of 14th previous fault
U16
Upper 2 bytes
213
D5
U16
Lower 2 bytes
Resolution 0.25 hr
7
7
Fuel / Air
V2V
Standard
Current stepper motor position
S16
Position scaled by 4
(i.e. value of 4 is one full step)