Sensepoint XCD RTD Technical Manual SPXCDHMRTEN Issue 1
19
The Earth Screen of the field cable should be “tied to Earth” or connected to Ground at
one point only. It is common practise to adopt a STAR EARTH connection regime where
all instrumentation Screens are connected at one common point.
The Screen at the other end of the cable should be “parked” or terminated into a blank
terminal.
The following diagrams show how to install the wire into the ground screw of the
enclosure.
6.6 Ground Terminal Wiring
Internal Ground connection: Utilize the shield of the wiring cable recommended in the
wiring instructions. For connection to this terminal. Twist the shield wire to avoid stray
shield wires, Loosen the screw sufficiently and wrap the wire around the screw in a “U”
shape. Raise the clamp and place the wire between the clamp and ground base, lower the
clamp and tighten the screw to 6.9lb-in torque.
External Ground Connection: If required by local authority, Utilize a No 14 AWG copper,
(Stranded or Solid), wire. Loosen the screw sufficiently to enable ‘wrapping the wire
around the screw in a “U” shape. Raise the clamp and place the wire between the clamp
and ground base, lower the clamp and tighten the screw to10.4lb-in torque.
Loosen the bolt
Insert cable
Fasten the bolt
Summary of Contents for Sensepoint XCD RTD
Page 1: ...Technical Manual Sensepoint XCD RTD Remote Toxic Detector Technical Manual ...
Page 56: ...Sensepoint XCD RTD Technical Manual SPXCDHMRTEN Issue 1 56 17 5 Mounting Bracket Drawing ...
Page 58: ...Sensepoint XCD RTD Technical Manual SPXCDHMRTEN Issue 1 58 China GB Ex English Version ...
Page 59: ...Sensepoint XCD RTD Technical Manual SPXCDHMRTEN Issue 1 59 China PA Certification ...
Page 60: ...Sensepoint XCD RTD Technical Manual SPXCDHMRTEN Issue 1 60 18 2 Korea KTL ...
Page 63: ...Sensepoint XCD RTD Technical Manual SPXCDHMRTEN Issue 1 63 ATEX for Sensor ...
Page 65: ...Sensepoint XCD RTD Technical Manual SPXCDHMRTEN Issue 1 65 IEC Ex for Sensor ...
Page 66: ...Sensepoint XCD RTD Technical Manual SPXCDHMRTEN Issue 1 66 18 5 ATEX Name Plate ...