Sensepoint XCD RTD Technical Manual SPXCDHMRTEN Issue 1
39
12.3 Faults and Warnings
The table below provides details of possible error.
Message
Description
Action
W-01
Calibration needed
The unit has not been calibrated for the
configured calibration interval
Calibration is necessary due to change
of sensor/gas type
W-02
Transmitter Temperature
limits exceeded
Use ‘
’ to clear when within limits
W-03
Alarm setting needs to be
configured
Re-configure alarm settings such that
upper alarm should not exceed user
configured scale
F-01
Internal I2C failure
Cycle power to detector. Replace
detector
F-02
Cell failure or Over range
Replace sensor or Check the input
signal wiring.
F-03
Significant zero drift
Re zero/calibrate
F-04
Unexpected sensor fitted
Replace sensor
F-05
EEPROM is corrupted
Reset transmitter. If fault still appear,
replace transmitter
F-06
Low supply voltage
Reset transmitter. If fault still appear,
replace transmitter
F-07
SRS processor failure
Reset transmitter. If fault still appear,
replace transmitter
F-08
RAM read/write fault
Reset transmitter. If fault still appear,
replace transmitter
F-09
Info. memory corrupted
Reset transmitter. If fault still appear,
replace transmitter
F-10
Code Memory corrupted
Reset transmitter. If fault still appear,
replace transmitter
F-11
DAC output failure
Check load resistor or sink/source mode
switch was configured properly
F-12
Heater failure
Reset transmitter. If fault still appear,
replace transmitter
F-13
Supplied voltage failure
Check supply voltage. Replace detector
Table 7: Fault and Warning List
Summary of Contents for Sensepoint XCD RTD
Page 1: ...Technical Manual Sensepoint XCD RTD Remote Toxic Detector Technical Manual ...
Page 56: ...Sensepoint XCD RTD Technical Manual SPXCDHMRTEN Issue 1 56 17 5 Mounting Bracket Drawing ...
Page 58: ...Sensepoint XCD RTD Technical Manual SPXCDHMRTEN Issue 1 58 China GB Ex English Version ...
Page 59: ...Sensepoint XCD RTD Technical Manual SPXCDHMRTEN Issue 1 59 China PA Certification ...
Page 60: ...Sensepoint XCD RTD Technical Manual SPXCDHMRTEN Issue 1 60 18 2 Korea KTL ...
Page 63: ...Sensepoint XCD RTD Technical Manual SPXCDHMRTEN Issue 1 63 ATEX for Sensor ...
Page 65: ...Sensepoint XCD RTD Technical Manual SPXCDHMRTEN Issue 1 65 IEC Ex for Sensor ...
Page 66: ...Sensepoint XCD RTD Technical Manual SPXCDHMRTEN Issue 1 66 18 5 ATEX Name Plate ...