— 51 —
A = DEVICE ACTION
0 = No Response; 1 = Close for 2 sec; 2 = Close and stay closed; 3 = Pulse on and off; 4 =
Toggle alternately between START and STOP events
EV = EVENT
0 = Not used; 1 = Alarm; 2 = Fault; 3 = Trouble; 4 = Restore
ZL = ZONE LIST
01-15, 00 = Not Used
"START" ZONE LIST:
Upon alarm, fault, trouble or restore of ANY zone in this list, device
action will START.
"STOP" ZONE LIST:
Upon restore of ALL zones on this list, device action will STOP. It
need not be same list as used for START.
ZT = ZONE TYPE/SYSTEM OPERATION
Choices for Zone Type/System Operation are:
00 = No Response (Not Used)
21 = Arming-AWAY****
41 = AC Power Fail
01 = Entry/Exit #1
22 = Disarming (Code + Off)
42 = System Battery Low
02 = Entry/exit #2
23 = No Alarm Response
43 = Communication Failure
03 = Perimeter
44 = RF Low Battery
04 = Interior Follower
45 = Polling Loop Failure
05 = Trouble Day/Alarm Night
27 = Access Point (allows more than one
relay to be controlled by activation if
access point request) - Not Used
47 = Console Failure
06 = 24-Hr. Silent
28 = MLB Supervision - Not Used
51 = RF Receiver Failure
07 = 24-Hr. Audible
29 = Momentary Exit - Not Used
52 = Kissoff
08 = 24-Hr. Auxiliary
30 = On Second Code + Off
54 = Fire Zone Reset
09 = Fire Alarm or Trouble
31 = End of Exit Time
55 = 1 Minute
10 = Interior W/Delay
32 = Start of Entry Time
56 = XX Minutes (enter XX in field 1*74) *
12 = PLM Supervision - Not
Used
33 = Any Burglary Alarm
57 = YY Seconds (enter YY in field 1*75) *
13 = Remote P/S
34 = Code + [#] + 71
58 = Duress
14 = CO Detector Alarm
35 = Code + [#] + 72
16 = Fire With Verification
36 = At Bell Timeout **
17 = Waterflow*****
37 = 2 Times Bell Timeout **
60 = Audio Alarm Verification (must be
selected for both START and STOP
operation)
18 = Fire Supervisory
38 = Chime
61 = Code + [#] + 67
19 = 24-Hour Trouble
39 = Fire Alarm
62 = Bell 2 Timeout
20 = Arming-STAY***
40 = Bypassing
63 = Auxiliary Relay Timeout
*
Stop condition only
**
Or at disarming, whichever occurs earlier
*** The output also activates when the partition is armed in the INSTANT mode
**** The output also activates when the partition is armed in the MAXIMUM mode
***** Use an event of fault or alarm as the START option
P = PARTITION No.
1-2, 0 = Any
ZONE LISTS FOR OUTPUT DEVICES
– Programmed in the #93 Menu Mode in the Output Programming Section. Fill in the
required data on the worksheet below and follow the procedure shown earlier in this
Programming Guide as you enter the
data during the displays and prompts that appear in sequence. Up to 15 zone lists may be created
NOTE
:
Record desired zone numbers below. More or fewer boxes than shown may be needed, as any list may include
any or
all of system's zone numbers.
Zone List 1
: Started or stopped by zone numbers (enter 000 to end entries).
Zone List 2:
Started or stopped by zone numbers (enter 000 to end entries).
Zone List 3:
Started or stopped by zone numbers (enter 000 to end entries).
Zone List 4:
Started or stopped by zone numbers (enter 000 to end entries).