– 16 –
Programming With #93 Menu Mode
NOTE: The following field should be preset before beginning: 2*00 Number of Partitions. In addition, receivers should
be programmed via Device programming.
After programming all system related programming fields in the usual way, press #93 while still in programming mode to
display the first choice of the menu driven programming functions. Press 0 (NO) or 1 (YES) in response to the displayed menu
selection. Pressing 0 will display the next choice in sequence.
#93 MENU MODE KEY COMMANDS
The following is a list of commands used while in the menu mode.
#93
Enters Menu mode
[
✱
]
Serves as ENTER key. Press to have keypad accept entry.
[#]
Backs up to previous screen.
0
Press to answer NO
1
Press to answer YES
001-009
All data entries are either 2-digit or 3-digit entries.
000
Exits menu mode, back into field programming mode, when entered at the first question for each category.
Menu selections are as follows:
PROMPT
EXPLANATION
ZONE PROG?
1 = YES 0 = NO
0
For programming the following:
• Zone
Number
•
Zone Response Type
•
Partition Number for Zone
•
Dialer report code for zone
•
Input Device Type for zone (whether RF, polling loop, etc.)
•
Enrolling serial numbers of 5800 Series transmitters & serial polling loop devices into the system.
•
Zone Attributes (e.g., Arm w/Fault, Silent, etc.)
EXPERT MODE?
1 = YES 0 = NO
0
Same as Zone Programming except:
•
Done with a minimum number of keystrokes.
•
Can program wireless keys using pre-defined templates.
NOTE:
Be aware some of the zone attributes cannot be programmed in the Expert Mode. These can only be
done in Zone Programming.
REPORT CODE PROG?
1 = YES 0 = NO
0
For programming the following:
•
Alarm report codes for zones
•
Restore & supervisory codes
•
All other system report codes
ALPHA PROG?
1 = YES 0 = NO
0
For entering alpha descriptors for the following:
• Zone
Descriptors
• Default
Screen
• Custom
Words
• Partition
Descriptors
DEVICE PROG?
1 = YES 0 = NO
0
For defining the following device characteristics for addressable devices, including keypads, RF receivers
(5881ENHC, 5883H), output relay modules (4204/4204CF), and Communicators (7845i-ent).
• Device
Address
• Device
Type
•
Keypad Options (incl. partition assignment)
• RF
House
ID
•
Communicator Options (incl. programming communicators)
OUTPUT PGM?
1 = YES 0 = NO
0
For defining output relay functions.
RLY VOICE DESCR?
1 = YES 0 = NO
0
Not Used. Must be set to “0”.