background image

7 - 5

OCR User-Defined Variables

You can create up to two of your own user variables for an OCR template.  These variables will represent 
any OCR readable characters.  The user-defined variables are stored under the letters “g” and “h.”  Cre-
ating a user variable follows the same steps as creating a template, but instead of scanning the 

Enter 

OCR Template 

symbol, you scan the 

Enter User-Defined Variable

 symbol (

page 7-10

).  The letters g 

and h can then be used in an OCR template to define the variable you specified.

Example:

You need a variable to represent the letters “A,” “B,” or “C.”  The template for this variable 
would be:

414243

To create this template, you would enable the OCR-A font.  Scan the 

Enter User-Defined Variable g

 

symbol (

page 7-10

).  Scan 

414243

 from the 

Programming Chart

 (the hex characters for “A,” “B,” and 

“C”).  Scan 

Save OCR Template 

(

page 7-10

).  This will let you read either A or B or C in any position 

where you place the g.  For example, you could create the following template:

ddddddggg

This template would then let you read data that began with six digits, and had an A, B, or C trailing.  So 
you would be able to read:

654321ABC

or

654321BAC

or

654321CCC

Reading Multi-Row OCR

The  imager is capable of decoding multi-row OCR text.  

Note:

Reading rows longer than sixteen characters is not recommended.

Consider the following example.  This example shows serial commands as they would be entered using 
Quick*View.

Example:

  You need to read multiple rows of OCR-A data as shown below:

12345678
ABCDEFGH

First, enable the OCR-A font.  To read the first row of OCR data, you would program the following 
template:

OCRTMP"dddddddd".

This template is the default OCR template.  If you wanted to read the second line of data, you would 
use the following template: 

OCRTMP"llllllll".

Summary of Contents for 4800dr - Document Camera

Page 1: ...4800dr Document Reader Barcode Guide ...

Page 2: ...d by copyright All rights are reserved No part of this document may be photocopied reproduced or translated into another language without the prior written consent of HII 2007 2009 Honeywell International Inc All rights reserved Other product names or marks mentioned in this document may be trademarks or registered trademarks of other companies and are the property of their respective owners Web A...

Page 3: ...ger Out of the Stand 1 6 Chapter 2 Terminal Interfaces Keyboard Country 2 1 Keyboard Style 2 2 Keyboard Modifiers 2 3 TTL 232 Baud Rate 2 4 RS 232 Word Length Data Bits Stop Bits and Parity 2 5 TTL 232 Receiver Time Out 2 5 RS 232 Handshaking 2 5 Chapter 3 Output Good Read Indicators 3 1 Beeper Good Read 3 1 Beeper Volume Good Read 3 1 Beeper Pitch Good Read 3 1 Beeper Duration Good Read 3 2 LED G...

Page 4: ...uffix Overview 4 1 To Add a Prefix or Suffix 4 2 To Clear One or All Prefixes or Suffixes 4 2 To Add a Carriage Return Suffix to all Symbologies 4 3 Prefix Selections 4 3 Suffix Selections 4 3 Function Code Transmit 4 4 Intercharacter Interfunction and Intermessage Delays 4 4 Intercharacter Delay 4 4 User Specified Intercharacter Delay 4 4 Interfunction Delay 4 5 Intermessage Delay 4 5 Chapter 5 D...

Page 5: ...ode 128 6 12 ISBT 128 Concatenation 6 12 Code 128 Code Page 6 13 Telepen 6 14 UPC A 6 15 UPC A EAN 13 with Extended Coupon Code 6 16 UPC E0 6 17 UPC E1 6 18 EAN JAN 13 6 19 ISBN Translate 6 20 EAN JAN 8 6 21 MSI 6 22 Plessey Code 6 23 GS1 DataBar 6 24 GS1 DataBar Limited 6 24 GS1 DataBar Expanded 6 24 PosiCode 6 25 Trioptic Code 6 25 Codablock F 6 26 Code 16K 6 27 Code 49 6 28 PDF417 6 29 MicroPDF...

Page 6: ...eating an OCR Template 7 3 Stringing Together Multiple Formats Creating Or Statements 7 4 OCR User Defined Variables 7 5 Reading Multi Row OCR 7 5 OCR Check Character 7 6 OCR Modulo 10 Check Character 7 6 OCR Modulo 36 Check Character 7 7 OCR User Defined Check Character 7 7 Weighting Options 7 8 OCR ISBN Application Example 7 9 OCR Template Codes 7 10 Chapter 8 Interface Keys Keyboard Function Re...

Page 7: ...d Product Defaults 10 3 Menu Commands 10 4 Chapter 11 Product Specifications Standard Cable Pinouts 11 3 Serial Output 11 3 USB 11 3 Chapter 12 Maintenance Repairs 12 1 Maintenance 12 1 Cleaning the Document Reader 12 1 Inspecting Cords and Connectors 12 1 Replacing the Interface Cable 12 1 Troubleshooting 12 2 Chapter 13 Customer Support Technical Assistance 13 1 Online Technical Assistance 13 1 ...

Page 8: ...vi OCR Programming Chart Programming Chart ...

Page 9: ...ing carton take the following steps Check for damage during shipment Report damage immediately to the carrier who delivered the carton Make sure the items in the carton match your order Save the shipping container for later storage or shipping The packaging for this device is as eco friendly as we could make it Please recycle the packaging Document Reader Models The chart below lists the interface...

Page 10: ...formation refer to Honeywell USB Application Note available at www honeywell com aidc Connecting the Document Reader with TTL 232 Serial Port Note See Document Reader Models on page 1 1 to determine which interfaces apply to your document reader 1 Turn off power to the terminal computer 2 Connect the appropriate interface cable to the document reader Note For the document reader to work properly y...

Page 11: ...lug and Play codes to program the document reader for IBM SurePos USB Hand Held document reader or IBM SurePos USB Tabletop document reader Note After scanning one of these codes you must power cycle the cash register Each barcode above also programs the following suffixes for each symbology Terminal Terminal ID TTL 232 000 USB COM Port Emulation 130 default USB PC Keyboard 124 USB Mac Keyboard 12...

Page 12: ...lowing code to program the document reader to emulate a regular TTL 232 based COM port If you are using a Microsoft Windows PC you will need to download a driver from the Honey well website www honeywell com aidc The driver will use the next available COM port number Apple Macintosh computers recognize the document reader as a USB CDC class device and automat ically use a class driver Scanning the...

Page 13: ...e screw in the base tray with a coin 2 Place the alignment page on the tray Align the upper left corner of the alignment page to the upper left corner of the tray 3 Make sure the serial number on the alignment page the top number matches the serial number on your document reader 4 Press the button on the imager to display the illuminated aimer crosshairs You will hear a single beep that indicates ...

Page 14: ... should be read farther from the unit To read single or multi ple symbols on a page or on an object hold the barcode at an appropriate distance from the document reader press the trigger and center the aimer on the symbol If the code being scanned is highly reflec tive e g laminated it may be necessary to tilt the code 5 to prevent unwanted reflection Using the Imager Out of the Stand If you remov...

Page 15: ...your country As a general rule the following characters are supported but need special care for countries other than the United States United States Brazil Czech Republic Denmark Finland Sweden France Germany Austria Greece Hungary Belgium Canada French Israel Hebrew Italy Latin America Norway Netherlands Dutch ...

Page 16: ...country other than one listed above scan the Program Keyboard Country barcode below then scan the numeric barcode s for the appropriate country from the inside back cover then the Save barcode Keyboard Style This programs keyboard styles such as Caps Lock and Shift Lock Default Regular Poland Portugal Romania Russia SCS Slovakia Spain Sweden Switzerland German Turkey F Turkey Q U K Program Keyboar...

Page 17: ...tus Autocaps via NumLock barcode should be scanned in countries e g Germany France where the Caps Lock key cannot be used to toggle Caps Lock The NumLock option works similarly to the regular Auotcaps but uses the NumLock key to retrieve the current state of the Caps Lock Emulate External Keyboard should be scanned if you do not have an external keyboard IBM AT or equivalent Note After scanning th...

Page 18: ... Sends numeric characters as if entered from a numeric keypad Default Off TTL 232 Baud Rate Baud Rate sends the data from the document reader to the terminal at the specified rate The host ter minal must be set for the same baud rate as the document reader Default 115 200 Control ASCII Mode On Control ASCII Mode Off Numeric Keypad Mode On Numeric Keypad Mode Off 300 2400 600 1200 4800 38400 9600 1...

Page 19: ... the CTS line will also wake up the receiver The receiver takes 300 milliseconds to completely come up Change the TTL 232 receiver time out by scan ning the barcode below then scanning digits from the inside back cover of this manual then scanning Save The range is 0 to 300 seconds Default 0 seconds no time out always on RS 232 Handshaking TTL 232 Handshaking allows control of data transmission fr...

Page 20: ...o resume transmission the host sends the XON character DC1 hex 11 Data transmission continues where it left off when XOFF was sent Default RTS CTS XON XOFF and ACK NAK Off RTS CTS On XON OFF Off RTS CTS Off XON XOFF On ACK NAK On ACK NAK Off ...

Page 21: ...ion All error and menu beeps are still audible Default On Beeper Volume Good Read The beeper volume codes modify the volume of the beep the document reader emits on a good read Default Medium Beeper Pitch Good Read The beeper pitch codes modify the pitch frequency of the beep the document reader emits on a good read Default Medium On Off High Medium Off Low Low 1600 Hz Medium 3250 Hz High 4200 Hz ...

Page 22: ... its idle state It blinks Off for a good read then returns to its idle On state LED Indicator On can also be used as a power on indicator Default LED Indicator Off Number of Beeps Good Read The number of beeps of a good read can be programmed from 1 9 The same number of beeps will be applied to the beeper and LED in response to a good read For example if you program this option to have five beeps ...

Page 23: ... reader scans until a barcode is read or until the trigger is released When in serial mode the document reader scans until a barcode has been read or until the deactivate command is sent In serial mode the document reader can also be set to turn itself off after a specified time has elapsed see Read Time Out which follows Read Time Out Use this selection to set a time out in milliseconds of the do...

Page 24: ...Power Level on page 3 6 This mode requires at least 50 lux of ambient light to operate correctly Scan Stand Symbol When a unit is in Scan Stand mode the LEDs shine at the Scan Stand Symbol on the base of the stand which tells it to remain idle When the Scan Stand symbol is covered the document reader turns the LEDs on at the configured power level Default High and attempts to find and decode barco...

Page 25: ...in in manual trigger mode by setting the Hands Free Time Out Once the time out value is reached if there have been no further trigger pulls the document reader reverts to the original hands free mode Scan the Hands Free Time Out barcode then scan the time out duration from 0 300 000 milliseconds from the inside back cover and Save Default 5 000 ms Reread Delay This sets the time period before the ...

Page 26: ...100 power during the delay regardless of the LED Power Level Default High Note If you scan the Off barcode both the aimer and illumination lights turn off making it impossible to scan barcodes in low light To turn the LED Power Level back on move to a brightly lit area and scan either the Low or the High barcode below Imager Time Out Imager Time Out powers down the document reader after the unit h...

Page 27: ...ature allows you to turn the aimer on and off When the Interlaced barcode is scanned the aimer is interlaced with the illumination LEDs Default Interlaced Centering Use Centering to narrow the document reader s field of view to make sure the document reader reads only those barcodes intended by the user For instance if multiple codes are placed closely together centering will insure that only the ...

Page 28: ...e decoded or output by the document reader If centering is turned on by scanning Centering On the document reader only reads codes that inter sect the centering window you specify using the Top Bottom Left or Right barcodes Scan Centering On then scan one of the following barcodes to change the top bottom left or right of the centering window Then scan the percent you want to shift the centering w...

Page 29: ...iew The 4800dr defaults to Decode Win dow On Decode Window X at 68 and Decode Window Y at 60 this emulates the decode area of our other imaging products If you want the decode window to use the full field of view scan the Decode Window Off Full FOV bar code Note that this slows decode time To set a decode window scan the Decode Window On barcode Next set the percentage of the field of view for the...

Page 30: ...other sym bologies in situations where both barcode symbologies appear on the same label but the lower priority symbology cannot be disabled For example you may be using the document reader in a retail setting to read UPC symbols but have occasional need to read a code on a drivers license Since some licenses have a Code 39 symbol as well as the PDF417 symbol you can use Preferred Symbology to spe...

Page 31: ...ou want to set additional low priority symbologies scan FF then scan the 2 digit hex value from the Programming Chart for the next symbology You can program up to 5 low priority symbologies Scan Save to save your selection Default None Preferred Symbology Time out Once you have enabled Preferred Symbology and entered the high and low priority symbologies you must set the time out period This is th...

Page 32: ...eading each barcode in the sequence To Add an Output Sequence 1 Scan the Enter Sequence symbol see Require Output Sequence page 3 14 2 Code I D On the Symbology Chart on page A 1 find the symbology to which you want to apply the output sequence format Locate the Hex value for that symbology and scan the 2 digit hex value from the Programming Chart inside back cover 3 Length Specify what length up ...

Page 33: ...ier for Code 93 9999 code length that must match for Code 93 9999 all lengths 43 start character match for Code 93 43h C FF termination string for third code To program the previous example using specific lengths you would have to count any programmed pre fixes suffixes or formatted characters as part of the length If you use the example on page 3 13 but assume a CR suffix and specific code length...

Page 34: ...ta is output to the host as the document reader decodes it Default Off Note This selection is unavailable when the Multiple Symbols Selection is turned on Multiple Symbols When this programming selection is turned On it allows you to read multiple symbols with a single pull of the Document Reader s trigger If you press and hold the trigger aiming the Document Reader at a series of symbols it reads...

Page 35: ...canning the Set Print Weight barcode set the print weight from 1 7 by scanning digits from the inside back cover then scanning Save Default 4 Video Reverse Video Reverse is used to allow the document reader to read barcodes that are inverted The Off bar code below is an example of this type of barcode If additional menuing is required Video Reverse must be disabled to read the menu barcodes and th...

Page 36: ...tion sensitive For example KIX codes and OCR can misread when scanned sideways or upside down Use the working orientation settings if your direction sensitive codes will not usually be presented upright to the document reader Default Upright Mandatory Alignment Flag On Mandatory Alignment Flag Off Upright Rotate Code Clockwise 90 Upside Down Rotate Code Counterclockwise 90 Upright Rotate Code Cloc...

Page 37: ...nts to Keep In Mind It is not necessary to build a message string The selections in this chapter are only used if you wish to alter the default settings Default prefix None Default suffix None A prefix or suffix may be added or cleared from one symbology or all symbologies You can add any prefix or suffix from the ASCII Conversion Chart Code Page 1252 page A 3 plus Code I D and AIM I D You can str...

Page 38: ...to create the leading backslash and then to create the backslash itself Step 8 Scan Save to exit and save or scan Discard to exit without saving Repeat Steps 1 6 to add a prefix or suffix for another symbology Example Add a Suffix to a specific symbology To send a CR carriage return Suffix for UPC only Step 1 Scan Add Suffix Step 2 Determine the 2 digit hex value from the Symbology Chart included ...

Page 39: ...ver of this manual or scan 9 9 for all symbologies Your change is automatically saved To Add a Carriage Return Suffix to all Symbologies Scan the following barcode if you wish to add a carriage return suffix to all symbologies at once This action first clears all current suffixes then programs a carriage return suffix for all symbologies Prefix Selections Suffix Selections Add CR Suffix All Symbol...

Page 40: ...ter delay of up to 495 milliseconds in 5 ms steps may be placed between the transmis sion of each character of scanned data Scan the Intercharacter Delay barcode below then scan the number of 5 millisecond steps 0 99 and the Save barcode using the Programming Chart inside the back cover of this manual To remove this delay scan the Intercharacter Delay barcode then set the number of steps to 0 Scan...

Page 41: ...s manual To remove this delay scan the Interfunction Delay barcode then set the number of steps to 0 Scan the Save barcode using the Programming Chart inside the back cover of this manual Intermessage Delay An intermessage delay of up to 495 milliseconds in 5 ms steps may be placed between each scan transmission Scan the Intermessage Delay barcode below then scan the number of 5 millisecond steps ...

Page 42: ...4 6 ...

Page 43: ...versal Code ID Actual Length 8 Universal Term ID Universal Code ID Universal Length If you have changed data format settings and wish to clear all formats and return to the factory defaults scan the Default Data Format code on page 5 4 To Add a Data Format Step 1 Scan the Enter Data Format symbol page 5 4 Step 2 Primary Alternate Format Determine if this will be your primary data format or one of ...

Page 44: ...ver of this manual This exits saving any Data Format changes Discard from the Programming Chart inside the back cover of this manual This exits without saving any Data Format changes Data Format Editor Commands Send Commands F1 Send all characters followed by xx key or function code starting from current cursor position Syntax F1xx xx stands for the hex value for an ASCII code see ASCII Conversion...

Page 45: ...rt Code Page 1252 page A 3 Miscellaneous Commands FB Suppress all occurrences of up to 15 different characters starting at the current cursor position as the cursor is advanced by other commands When the FC command is encountered the sup press function is terminated The cursor is not moved by the FB command Syntax FBnnxxyy zz where nn is a count of the number of suppressed characters in the list a...

Page 46: ...r does not transmit the input data to the host device Alternate Data Formats Alternate formats allow you single shot capability to scan one barcode using a different data format than your primary format When data formats are programmed see page 5 1 you must input whether you are programming the primary format or an alternate format numbered 1 2 or 3 Enter Data Format Default Data Format Clear One ...

Page 47: ...the 3 alternate format barcodes below The document reader will scan the next barcode formatting the data with the selected alternate format then revert immediately to the primary format Alternate Data Format 1 Alternate Data Format 2 Alternate Data Format 3 ...

Page 48: ...5 6 ...

Page 49: ...herlands Post Intelligent Mail Barcode Korea Post Australian Post Matrix 2 of 5 Aztec Code MaxiCode British Post MicroPDF417 Canadian Post MSI China Post PDF417 Codabar Planet Code Codablock F Plessey Code Code 11 PosiCode A and B Code 128 Postnet Code 16K QR Code Code 39 GS1 DataBar Expanded Code 49 GS1 DataBar Limited Code 93 GS1 DataBar Data Matrix Straight 2 of 5 IATA EAN JAN 13 Straight 2 of ...

Page 50: ...gth and Save barcodes on the Programming Chart inside the back cover of this manual The minimum and maximum lengths and the defaults are included with the respective symbologies Codabar Default All Codabar Settings Codabar Codabar Start Stop Characters Start Stop characters identify the leading and trailing ends of the barcode You may either transmit or not transmit Start Stop characters Default D...

Page 51: ...d into one with the D characters omitted Default On Select Require to prevent the document reader from decoding a single D Codabar symbol without its companion This selection has no effect on Codabar symbols without Stop Start D characters Codabar Message Length Scan the barcodes below to change the message length Refer to Message Length Description page 6 2 for additional information Minimum and ...

Page 52: ...a with or with out a check character When Check Character is set to Validate but Don t Transmit the unit only reads Code 39 barcodes printed with a check character but will not transmit the check character with the scanned data When Check Character is set to Validate and Transmit the document reader only reads Code 39 bar codes printed with a check character and will transmit this character at the...

Page 53: ...that start with a space excluding the start and stop symbols and does not immediately transmit the data The document reader stores the data in the order in which the bar codes are read deleting the first space from each The document reader transmits the appended data when it reads a Code 39 barcode that starts with a character other than a space Default Off Code 32 Pharmaceutical PARAF Code 32 Pha...

Page 54: ...g If this is the case scan the barcode below select the code page with which the barcodes were created see Code Page Mapping of Printed Barcodes on page A 4 and scan the value and the Save barcode from the Programming Chart on the inside the back cover of this manual The data characters should then appear properly NUL U DLE P SPSPACE 0 0 V P P W p P SOH A DC1 Q A 1 1 A A Q Q a A q Q STX B DC2 R B ...

Page 55: ...the scanned data When Check Digit is set to Validate and Transmit the document reader only reads Interleaved 2 of 5 barcodes printed with a check digit and will transmit this digit at the end of the scanned data Default No Check Digit Interleaved 2 of 5 Message Length Scan the barcodes below to change the message length Refer to Message Length Description page 6 2 for additional information Minimu...

Page 56: ...ved does not display with the proper characters it may be because the barcode being scanned was created using a code page that is different from the one the host program is expecting If this is the case scan the barcode below select the code page with which the barcodes were created see Code Page Mapping of Printed Barcodes on page A 4 and scan the value and the Save barcode from the Programming C...

Page 57: ...dustrial Straight 2 of 5 Industrial Message Length Scan the barcodes below to change the message length Refer to Message Length Description page 6 2 for additional information Minimum and Maximum lengths 1 48 Minimum Default 4 Maximum Default 48 On Off Minimum Message Length Maximum Message Length ...

Page 58: ... 2 of 5 IATA Straight 2 of 5 IATA Message Length Scan the barcodes below to change the message length Refer to Message Length Description page 6 2 for additional information Minimum and Maximum lengths 1 48 Minimum Default 4 Maximum Default 48 On Off Minimum Message Length Maximum Message Length ...

Page 59: ...Scan the barcodes below to change the message length Refer to Message Length Description page 6 2 for additional information Minimum and Maximum lengths 1 80 Minimum Default 4 Maximum Default 80 Code 11 Default All Code 11 Settings Code 11 On Off Minimum Message Length Maximum Message Length On Off ...

Page 60: ... 128 Default All Code 128 Settings Code 128 ISBT 128 Concatenation In 1994 the International Society of Blood Transfusion ISBT ratified a standard for communicating crit ical blood information in a uniform manner The use of ISBT formats requires a paid license The ISBT 128 Application Specification describes 1 the critical data elements for labeling blood products 2 the current recommendation to u...

Page 61: ... Page Code pages define the mapping of character codes to characters If the data received does not display with the proper characters it may be because the barcode being scanned was created using a code page that is different from the one the host program is expecting If this is the case scan the barcode below select the code page with which the barcodes were created see Code Page Mapping of Print...

Page 62: ...ader reads symbols with start stop pattern 1 and decodes them as compressed numeric with optional full ASCII start stop pattern 2 Default AIM Telepen Output Telepen Message Length Scan the barcodes below to change the message length Refer to Message Length Description page 6 2 for additional information Minimum and Maximum lengths 1 60 Minimum Default 1 Maximum Default 60 On Off Original Telepen O...

Page 63: ...her the check digit should be transmitted at the end of the scanned data or not Default On UPC A Number System The numeric system digit of a U P C symbol is normally transmitted at the beginning of the scanned data but the unit can be programmed so it will not transmit it Default On On Off On Off Off On ...

Page 64: ...r 5 digit addenda listed on page 6 16 Default Not Required UPC A Addenda Separator When this feature is On there is a space between the data from the barcode and the data from the addenda When turned Off there is no space Default On UPC A EAN 13 with Extended Coupon Code Use the following codes to enable or disable UPC A and EAN 13 with Extended Coupon Code Default On 5 Digit Addenda Off 5 Digit A...

Page 65: ...PC E Expand expands the UPC E code to the 12 digit UPC A format Default Off UPC E0 Addenda Required When the addenda is Required the document reader will only read UPC E barcodes that have addenda Default Not Required UPC E0 Addenda Separator When this feature is On there is a space between the data from the barcode and the data from the addenda When turned off there is no space Default On UPC E0 ...

Page 66: ...ogrammed so it will not transmit it Default On UPC E0 Addenda This selection adds 2 or 5 digits to the end of all scanned UPC E data Default Off for both 2 Digit and 5 Digit Addenda UPC E1 Most U P C barcodes lead with the 0 number system For these codes use UPC E0 page 6 17 If you need to read codes that lead with the 1 number system use the UPC E1 On selection Default Off Off On Off On 5 Digit A...

Page 67: ...r the check digit should be transmitted at the end of the scanned data or not Default On EAN JAN 13 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN JAN 13 data Default Off for both 2 Digit and 5 Digit Addenda On Off Off On 5 Digit Addenda Off 5 Digit Addenda On 2 Digit Addenda Off 2 Digit Addenda On ...

Page 68: ... is a space between the data from the barcode and the data from the addenda When turned off there is no space Default On Note If you want to enable or disable EAN13 with Extended Coupon Code refer to UPC A EAN 13 with Extended Coupon Code page 6 16 ISBN Translate This selection causes EAN 13 Bookland symbols to be translated into their equivalent ISBN number for mat Default Off Not Required Requir...

Page 69: ...r the check digit should be transmitted at the end of the scanned data or not Default On EAN JAN 8 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN JAN 8 data Default Off for both 2 Digit and 5 Digit Addenda On Off Off On 5 Digit Addenda Off 5 Digit Addenda On 2 Digit Addenda Off 2 Digit Addenda On ...

Page 70: ...o space Default On MSI Default All MSI Settings MSI MSI Check Character Different types of check characters are used with MSI barcodes You can program the document reader to read MSI barcodes with Type 10 check characters Default Validate Type 10 but Don t Transmit When Check Character is set to Validate and Transmit the document reader will only read MSI barcodes printed with the specified type c...

Page 71: ...additional information Minimum and Maximum lengths 4 48 Minimum Default 4 Maximum Default 48 Plessey Code Default All Plessey Code Settings Plessey Code Plessey Message Length Scan the barcodes below to change the message length Refer to Message Length Description page 6 2 for additional information Minimum and Maximum lengths 4 48 Minimum Default 4 Maximum Default 48 Validate Type 10 and Transmit...

Page 72: ...r Limited GS1 DataBar Expanded Default All GS1 DataBar Expanded Settings GS1 DataBar Expanded GS1 DataBar Expanded Message Length Scan the barcodes below to change the message length Refer to Message Length Description page 6 2 for additional information Minimum and Maximum lengths 4 74 Minimum Default 4 Maximum On Off On Off On Off ...

Page 73: ...essage Length Description page 6 2 for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 48 Trioptic Code Note If you are going to scan Code 32 Pharmaceutical codes page 6 5 Trioptic Code must be off Minimum Message Length Maximum Message Length On Off A and B On No Limited A and B and Limited A On Limited B Off A and B and Limited B On Limited A Off Minimum...

Page 74: ...tings Codablock F Codablock F Message Length Scan the barcodes below to change the message length Refer to Message Length Description page 6 2 for additional information Minimum and Maximum lengths 1 2048 Minimum Default 1 Maximum Default 2048 On Off On Off Minimum Message Length Maximum Message Length ...

Page 75: ...Message Length Scan the barcodes below to change the message length Refer to Message Length Description page 6 2 for additional information Minimum and Maximum lengths 0 160 Minimum Default 1 Maximum Default 160 On Off Minimum Message Length Maximum Message Length ...

Page 76: ...essage Length Scan the barcodes below to change the message length Refer to Message Length Description page 6 2 for additional information Minimum and Maximum lengths 1 81 Minimum Default 1 Maximum Default 81 On Off Minimum Message Length Maximum Message Length ...

Page 77: ...w to change the message length Refer to Message Length Description page 6 2 for additional information Minimum and Maximum lengths 1 2750 Minimum Default 1 Maximum Default 2750 MicroPDF417 Default All MicroPDF417 Settings MicroPDF417 Off On Maximum Message Length Minimum Message Length Off On ...

Page 78: ...AN UCC Composite symbology EAN UCC Composite symbologies allow for the co existence of sym bologies already in use UPC EAN Version Scan the UPC EAN Version On barcode to decode EAN UCC Composite symbols that have a UPC or EAN linear component This does not affect EAN UCC Composite symbols with a UCC EAN 128 or GS1 DataBar linear component If either of these codes are the linear component either Co...

Page 79: ...28 Emulation is selected the AIM Symbology Identifier is reported as C1 If GS1 DataBar Emulation is selected the AIM Symbology Identifier is reported as e0 Any application that accepts EAN UCC data can be sim plified since it only needs to recognize one data carrier type Default EAN UCC Emulation Off TCIF Linked Code 39 TLC39 This code is a composite code since it has a Code 39 linear component an...

Page 80: ... ID tag UPU 4 State Postnet Postnet Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data Off On Off On Off On Don t Transmit Check Digit Transmit Check Digit ...

Page 81: ... the end of the scanned data British Post Canadian Post Kix Netherlands Post Note Kix code can misread when scanned sideways or upside down Use Working Orientation page 3 16 if your Kix codes will not usually be presented upright to the document reader Off On Don t Transmit Check Digit Transmit Check Digit Off On Off On Off On ...

Page 82: ...Bar Output lists the bar patterns in 0123 format Numeric N Table causes that field to be interpreted as numeric data using the N Table Alphanumeric C Table causes the field to be interpreted as alphanu meric data using the C Table Refer to the Australian Post Specification Tables Default Bar Output Off On Numeric N Table Bar Output Alphanumeric C Table ...

Page 83: ...na Post Message Length Scan the barcodes below to change the message length Refer to Message Length Description page 6 2 for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 80 Off On On Off Minimum Message Length Maximum Message Length ...

Page 84: ...he message length Refer to Message Length Description page 6 2 for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 48 QR Code Default All QR Code Settings QR Code This selection applies to both QR Code and Micro QR Code On Off Minimum Message Length Maximum Message Length Off On ...

Page 85: ...500 Data Matrix Default All Data Matrix Settings Data Matrix Data Matrix Message Length Scan the barcodes below to change the message length Refer to Message Length Description page 6 2 for additional information Minimum and Maximum lengths 1 1500 Minimum Default 1 Maximum Default 1500 MaxiCode Default All MaxiCode Settings Maximum Message Length Minimum Message Length Off On Maximum Message Lengt...

Page 86: ...ult 1 Maximum Default 150 Aztec Code Default All Aztec Code Settings Aztec Code Aztec Code Message Length Scan the barcodes below to change the message length Refer to Message Length Description page 6 2 for additional information Minimum and Maximum lengths 1 3750 Minimum Default 1 Maximum Default 3750 Off On Maximum Message Length Minimum Message Length Off On Maximum Message Length Minimum Mess...

Page 87: ...9 Aztec Runes Select Enable Runes if you are scanning Aztec runes which are the smallest type of Aztec Code sym bol with the ability to encode a very short license plate message Disable Runes Enable Runes ...

Page 88: ...6 40 ...

Page 89: ...ts Default All OCR Settings turns off all OCR capability in the imager so the imager will be able to scan linear stacked matrix and composite barcodes but not OCR fonts In addition any OCR templates you have created are erased The eight digit default templates are reinstated for any future use of the OCR On codes listed below Default All OCR Settings OCR Note OCR symbols can misread when scanned s...

Page 90: ...you to scan the SEMI font used in the semiconductor industry All OCR Off turns off all OCR capability in the imager so the imager will be able to scan linear stacked matrix and composite barcodes but not OCR fonts However any OCR templates you have created will be retained in memory OCR Templates You can create a custom template or character string that defines the length and content of OCR string...

Page 91: ...the d from the OCR Programming Chart in the back of this manual eight times Scan Save OCR Template page 7 10 This would let you read any string of eight digits for example 37680981 Character Match Sequences This method is used if you need a template that shows a specific character in a specific position Put the character in uppercase in the template at the required position template characters are...

Page 92: ...equences above to add spaces to a string The hex value for a space is 20 4 Exit OCR Template Editor Scan Save OCR Template to save your entries Discard OCR Template exits without saving any OCR Template changes Stringing Together Multiple Formats Creating Or Statements You may want to program the imager to accept many OCR formats To do this you would string together each format with a t This tells...

Page 93: ...e hex characters for A B and C Scan Save OCR Template page 7 10 This will let you read either A or B or C in any position where you place the g For example you could create the following template ddddddggg This template would then let you read data that began with six digits and had an A B or C trailing So you would be able to read 654321ABC or 654321BAC or 654321CCC Reading Multi Row OCR The imag...

Page 94: ...gs you re scanning The imager will then only read OCR character strings with a valid check character The imager transmits the OCR data without the check character data You must specify the location of the check character in the template with a c Example You need to read any combination of seven digits with a modulo 10 check character in the eighth position The template would be dddddddc To create ...

Page 95: ... the OCR A font then scan the following string 6512351X The imager performs the following check character computation 6 5 1 2 3 5 1 X modulo 11 0 Since the result is zero the message is considered to be valid so the reader outputs the message 6512351 Programming a User Defined Check Character 1 Scan the Enter OCR Check Character barcode below 2 Enter the characters in order For each character look...

Page 96: ... the OCR template dddddddc Then scan the string below 01234565 The reader performs the check character computation below 0 x 3 1 x 1 2 x 3 3 x 1 4 x 3 5 x 1 6 x 3 5 x 1 modulo 10 0 Since the result is zero the message is considered to be valid so the reader outputs the message 0123456 2 1 2 1 Weighted Modulo 10 Check Character Starting with the check character and working backward through the mess...

Page 97: ...eps below you will be able to scan the following ISBN number or the additional data below it depending on the line of text at which the imager is aimed 1 Scan the OCR B On barcode on page 7 1 2 Program the user defined variable g to comprise the ten digits plus the dash 0123456789 3 In Japan it is common for two fields to follow the ISBN number the three digit price field and the four digit price ...

Page 98: ...programming command OCRENA2 TMP ISBNggggggggggggctCdddd hdddEtCdddd hddddE GPG 0123456789 GPH P CHK 0123456789X These commands can be encoded into the following Aztec Code symbol OCR Template Codes Note Reading more than three rows of OCR is not recommended Contact the factory if you have an application that requires reading four or more rows of OCR One or more two digit numbers and Save are requi...

Page 99: ...to US only The following chart indicates the equivalents of these five characters for different countries Function Code HEX ASCII Value Full ASCII CTRL NUL 00 SOH 01 A STX 02 B ETX 03 C EOT 04 D ENQ 05 E ACK 06 F BEL 07 G BS 08 H HT 09 I LF 0A J VT 0B K FF 0C L CR 0D M SO 0E N SI 0F O DLE 10 P DC1 11 Q DC2 12 R DC3 13 S DC4 14 T NAK 15 U SYN 16 V ETB 17 W CAN 18 X EM 19 Y SUB 1A Z ESC 1B FS 1C GS ...

Page 100: ... RETURN BS 08 Reserved BS 08 APPLE make HT 09 Tab HT 09 TAB LF 0A Reserved LF 0A APPLE break VT 0B Tab VT 0B TAB FF 0C Delete FF 0C Del CR 0D CR Enter CR 0D RETURN SO 0E Insert SO 0E Ins Help SI 0F Escape SI 0F ESC DLE 10 F11 DLE 10 F11 DC1 11 Home DC1 11 Home DC2 12 Print DC2 12 Prnt Scrn DC3 13 Back Space DC3 13 BACKSPACE DC4 14 Back Tab DC4 14 LSHIFT TAB NAK 15 F12 NAK 15 F12 SYN 16 F1 SYN 16 F...

Page 101: ...nit is power cycled Show Decoder Revision Scan the barcode below to output the decoder revision Show Engine Revision Scan the barcode below to output the engine revision The engine type revision number and status character ACK are returned Show Scan Driver Revision Scan the barcode below to output the scan driver revision The scan driver controls image capture Show Software Revision Scan the barco...

Page 102: ...ent of that programming code is output to the terminal Note This feature should not be used during normal document reader operation 2D PQA Print Quality Assessment Two dimensional Print Quality Assessment 2D PQA is a feature of Honeywell image readers where the data from the successful read of a 2D barcode symbol is augmented with lines of text that both identify the symbol and also report graded ...

Page 103: ... reader Visual Xpress requires that the PC have at least one available serial communication port or a serial port emulation using a physical USB port If you are using the serial port and TTL 232 cable an external power supply is required When using a USB serial port emu lation only a USB cable is required Visual Xpress Operations The Visual Xpress software performs the following operations Scan Da...

Page 104: ...ds Software 3 Click on the dropdown for Select Product Number Click on 4800DR 4 Click on the listing for Visual Xpress 5 When prompted select Save File and save the files to the c windows temp directory 6 Once you have finished downloading the file exit the web site 7 Using Explorer go to the c windows temp file 8 Double click on the Setup exe file Follow the screen prompts to install the Visual X...

Page 105: ...refix Three ASCII characters SYN M CR ASCII 22 77 13 Tag A 3 character case insensitive field that identifies the desired menu command group For example all TTL 232 configuration settings are identified with a Tag of 232 SubTag A 3 character case insensitive field that identifies the desired menu command within the tag group For example the SubTag for the TTL 232 baud rate is BAD Data The new valu...

Page 106: ...and are issued If the additional command requires a dif ferent Tag field the command is separated from previous commands by a semicolon Responses The device responds to serial commands with one of three responses ACK Indicates a good command which has been processed ENQ Indicates an invalid Tag or SubTag command NAK Indicates the command was good but the Data field entry was out of the allowable r...

Page 107: ...erial trigger commands First the document reader must be put in Manual Serial Trigger Mode either by scanning the Manual Serial Trigger Mode barcode page 3 3 or by sending the Manual Serial Menu Command page 10 6 Once the document reader is in serial trigger mode the trigger is activated and deactivated by sending the following com mands Activate SYN T CR Deactivate SYN U CR The document reader sc...

Page 108: ...um KBDCTY1 2 1 Brazil KBDCTY16 2 1 Canada French KBDCTY18 2 1 Czech Republic KBDCTY15 2 1 Denmark KBDCTY8 2 1 Finland Sweden KBDCTY2 2 1 France KBDCTY3 2 1 Germany Austria KBDCTY4 2 1 Greece KBDCTY17 2 1 Hungary KBDCTY19 2 1 Israel Hebrew KBDCTY12 2 1 Italy KBDCTY5 2 1 Latin America KBDCTY14 2 1 Netherlands Dutch KBDCTY11 2 1 Norway KBDCTY9 2 1 Poland KBDCTY20 2 2 Portugal KBDCTY13 2 2 Romania KBD...

Page 109: ...gth Data Bits Stop Bits and Parity 8 Data 1 Stop Parity Even 232WRD5 2 5 8 Data 1 Stop Parity None 232WRD2 2 5 8 Data 1 Stop Parity Odd 232WRD8 2 5 TTL 232 Receiver Time out Range 0 300 seconds 232LPT 2 5 TTL 232 Handshaking RTS CTS Off 232CTS0 2 6 RTS CTS On 232CTS1 2 6 XON XOFF Off 232XON0 2 6 XON XOFF On 232XON1 2 6 ACK NAK Off 232ACK0 2 6 ACK NAK On 232ACK1 2 6 Output Selections Beeper Good Re...

Page 110: ... 3 4 Scan Stand Symbol FNC3 3 4 Presentation Presentation Mode TRGMOD3 3 4 Presentation Sensitivity Range 0 20 1 TRGPMS 3 5 Hands Free Time Out Range 0 300 000 ms TRG PTO 3 5 Reread Delay Short 500 ms DLYRRD500 3 5 Medium 750 ms DLYRR750 3 5 Long 1000 ms DLYRRD1000 3 5 Extra Long 2000 ms DLYRRD2000 3 5 User Specified Reread Delay Range 0 30 000 ms DLYRRD 3 6 LED Power Level Off PWRLDC0 3 6 Low 50 ...

Page 111: ...rity Symbology PRFBLK 3 11 Preferred Symbology Timeout Range 100 3 000 ms PRFPTO 3 11 Preferred Symbology Default PRFDFT 3 11 Output Sequence Editor Enter Sequence SEQBLK 3 14 Default Sequence SEQDFT 3 14 Require Output Sequence Required SEQ_EN2 3 14 On Not Required SEQ_EN1 3 14 Off SEQ_EN0 3 14 Multiple Symbols On SHOTGN1 3 14 Off SHOTGN0 3 14 No Read On SHWNRD1 3 15 Off SHWNRD0 3 15 Print Weight...

Page 112: ...tter Selections Data Format Editor Default Data Format None DFMDF3 5 4 Enter Data Format DFMBK3 5 4 Clear One Data Format DFMCL3 5 4 Clear All Data Formats DFMCA3 5 4 Data Formatter Off DFM_EN0 5 4 On but Not Required DFM_EN1 5 4 On Required DFM_EN2 5 4 Alternate Data Formats 1 VSAF_1 5 5 2 VSAF_2 5 5 3 VSAF_3 5 5 Symbologies All Symbologies All Symbologies Off ALLENA0 6 1 All Symbologies On ALLEN...

Page 113: ...9MAX 6 5 Code 39 Append Off C39APP0 6 5 On C39APP1 6 5 Code 32 Pharmaceutical PARAF Off C39B320 6 5 On C39B321 6 5 Code 39 Full ASCII Off C39ASC0 6 6 On C39ASC1 6 6 Code 39 Code Page C39DCP 6 6 Interleaved 2 of 5 Default All Interleaved 2 of 5 Settings I25DFT 6 7 Interleaved 2 of 5 Off I25ENA0 6 7 On I25ENA1 6 7 Interleaved 2 of 5 Check Digit No Check Char I25CK20 6 7 Validate But Don t Transmit I...

Page 114: ...Settings X25DFT 6 11 Matrix 2 of 5 Off X25ENA0 6 11 On X25ENA1 6 11 Matrix 2 of 5 Message Length Minimum 1 80 4 X25MIN 6 11 Maximum 1 80 80 X25MAX 6 11 Code 11 Default All Code 11 Settings C11DFT 6 11 Code 11 Off C11ENA0 6 11 On C11ENA1 6 11 Code 11 Check Digits Required 1 Check Digit C11CK20 6 12 2 Check Digits C11CK21 6 12 Code 11 Message Length Minimum 1 80 4 C11MIN 6 12 Maximum 1 80 80 C11MAX ...

Page 115: ...UPAAD50 6 16 On UPAAD51 6 16 UPC A Addenda Required Not Required UPAARQ0 6 16 Required UPAARQ1 6 16 UPC A Addenda Separator Off UPAADS0 6 16 On UPAADS1 6 16 UPC A EAN 13 with Extended Cou pon Code On CPNENA1 6 16 Off CPNENA0 6 16 UPC E0 Default All UPC E Settings UPEDFT 6 17 UPC E0 Off UPEEN00 6 17 On UPEEN01 6 17 UPC E0 Expand Off UPEEXP0 6 17 On UPEEXP1 6 17 UPC E0 Addenda Required Required UPEA...

Page 116: ...d E13ARQ0 6 20 Required E13ARQ1 6 20 EAN JAN 13 Addenda Separator Off E13ADS0 6 20 On E13ADS1 6 20 ISBN Translate Off E13ISB0 6 20 On E13ISB1 6 20 EAN JAN 8 Default All EAN JAN 8 Settings EA8DFT 6 21 EAN JAN 8 Off EA8ENA0 6 21 On EA8ENA1 6 21 EAN JAN 8 Check Digit Off EA8CKX0 6 21 On EA8CKX1 6 21 EAN JAN 8 Addenda 2 Digit Addenda Off EA8AD20 6 21 2 Digit Addenda On EA8AD21 6 21 5 Digit Addenda Off...

Page 117: ...ult All GS1 DataBar Expanded Settings RSEDFT 6 24 GS1 DataBar Expanded Off RSEENA0 6 24 On RSEENA1 6 24 GS1 DataBar Expanded Msg Length Minimum 4 74 4 RSEMIN 6 25 Maximum 4 74 74 RSEMAX 6 25 PosiCode Default All PosiCode Settings POSDFT 6 26 PosiCode Off POSENA0 6 25 On POSENA1 6 25 A and B On POSLIM0 6 25 A and B and Limited A On POSLIM1 6 25 A and B and Limited B On POSLIM2 6 25 PosiCode Msg Len...

Page 118: ...imum 1 366 1 MPDMIN 6 30 Maximum 1 366 366 MPDMAX 6 30 EAN UCC Composite Codes On COMENA1 6 30 Off COMENA0 6 30 UPC EAN Version On COMUPC1 6 30 Off COMUPC0 6 30 EAN UCC Composite Codes Msg Length Minimum 1 2435 1 COMMIN 6 31 Maximum 1 2435 2435 COMMAX 6 31 EAN UCC Emulation GS1 DataBar Emulation EANEMU2 6 31 EAN UCC 128 Emulation EANEMU1 6 31 EAN UCC Emulation Off EANEMU0 6 31 TCIF Linked Code 39 ...

Page 119: ...0 80 CPCMAX 6 35 Korea Post Default All Korea Post Settings KPCDFT 6 36 Korea Post Off KPCENA0 6 36 On KPCENA1 6 36 Korea Post Msg Length Minimum 2 80 4 KPCMIN 6 36 Maximum 2 80 48 KPCMAX 6 36 QR Code Default All QR Code Settings QRCDFT 6 36 QR Code On QRCENA1 6 36 Off QRCENA0 6 36 QR Code Msg Length Minimum 1 3500 1 QRCMIN 6 37 Maximum 1 3500 3500 QRCMAX 6 37 Data Matrix Default All Data Matrix S...

Page 120: ...NA3 7 2 MICR E 13 B On OCRENA4 7 2 SEMI Font OCRENA5 7 2 All OCR Off OCRENA0 7 2 OCR Check Character OCR Mod 10 Check Char OCRCHK012345 6789 7 6 OCR Mod 36 Check Char OCRCHK012345 6789ABCDEFGHI JKLMNOPQRSTU VWXYZ 7 7 OCR User Defined Check Char OCRCHK 7 7 3 1 3 1 Weighted Mod 10 Check Char OCRCHK3 1 3 1 7 8 2 1 2 1 Weighted Mod 10 Check Char OCRCHK2 1 2 1 7 8 OCR Templates Enter OCR Template OCRTM...

Page 121: ...put Skew Angle 45 degrees Pitch Angle 45 degrees Motion Tolerance 100 UPC 3 inches 7 62cm per second Symbol Contrast Grade 1 0 20 or greater Voltage Requirements 4 5 5 VDC at imager Current Draw Typical Scanning 370mA Inrush 500mA Power Supply Noise Rejection Max 100 mV peak to peak 10 to 100 KHz Temperature Ranges Operating 32 F to 122 F 0 C to 50 C Storage 4 F to 140 F 20 C to 60 C Humidity 5 to...

Page 122: ...25 1 USA FCC Part 15 Subpart B Class B UL 60950 1 I T E CDRH Laser Class 2 Canada cUL CSA C22 2 No 60950 1 I T E CAN CSA CEI IEC CISPR 22 02 Class B European Community 2004 108 EC EMC Directive 2006 95 EC Low Voltage Directive Germany Gebprüfte Sicherheit GS marked and certified Australia C Tick marked for AS NZS 3548 ...

Page 123: ... power 4 Supply ground 5 Receive data Serial data to document reader 6 Transmit data Serial data from document reader 7 5 Volt power connection 8 Request to send data 9 Clear to send data 10 10 Pin Modular Plug connects to the document reader handle 1 2 Data 3 Tied to 5 volt power 4 Supply ground 5 6 7 5 volt power connection 8 9 10 Data ...

Page 124: ...11 4 ...

Page 125: ... be cleaned the same way Inspecting Cords and Connectors Inspect the document reader s interface cable and connector for wear or other signs of damage A badly worn cable or damaged connector may interfere with document reader operation Contact your distribu tor for information about cable replacement Cable replacement instructions are on page 12 1 Replacing the Interface Cable The standard interfa...

Page 126: ...ed check that The cable is connected properly The host system power is on if external power isn t used The trigger works Is the document reader having trouble reading your barcodes If the document reader isn t reading barcodes well check that the barcodes Aren t smeared rough scratched or exhibiting voids Aren t coated with frost or water droplets on the surface Are enabled in the document reader ...

Page 127: ...ter 6 The document reader won t read your barcode at all 1 Scan the sample barcodes in the back of this manual If the document reader reads the sample bar codes check that your barcode is readable Verify that your barcode symbology is enabled see Chapter 6 2 If the document reader still can t read the sample barcodes scan All Symbologies on page 6 1 If you aren t sure what programming options have...

Page 128: ...12 4 ...

Page 129: ... Africa Telephone 31 0 40 7999 393 Fax 31 0 40 2425 672 E mail eurosupport honeywell com Asia Pacific Telephone Hong Kong 852 3188 3485 or 2511 3050 Telephone China 86 21 6361 3818 E mail aptechsupport honeywell com Japan Telephone 813 3839 8511 E mail aptechsupport honeywell com Malaysia Telephone 603 6201 7020 E mail aptechsupport honeywell com Online Technical Assistance You can also access tec...

Page 130: ...rvice and repair assistance online at www honeywell com aidc Limited Warranty Honeywell International Inc HII warrants its products and optional accessories to be free from defects in materials and workmanship and to conform to HII s published specifications applicable to the products purchased at the time of shipment This warranty does not cover any HII product which is i improperly installed or ...

Page 131: ...E REPAIR OR REPLACEMENT OF THE DEFECTIVE PRODUCT WITH NEW OR REFURBISHED PARTS IN NO EVENT SHALL HII BE LIABLE FOR INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES AND IN NO EVENT SHALL ANY LIABILITY OF HII ARISING IN CON NECTION WITH ANY PRODUCT SOLD HEREUNDER WHETHER SUCH LIABILITY ARISES FROM A CLAIM BASED ON CONTRACT WARRANTY TORT OR OTHERWISE EXCEED THE ACTUAL AMOUNT PAID TO HII FOR THE PRODUCT T...

Page 132: ...13 4 ...

Page 133: ...1 2 4 j 0x6A Code 16K Km 0 1 2 4 o 0x6F Code 32 Pharmaceutical PARAF X0 0x3C Code 39 Am 0 1 3 4 5 7 b 0x62 Code 49 Tm 0 1 2 4 l 0x6C Code 93 and 93i Gm 0 9 A Z a m i 0x69 Data Matrix dm 0 6 w 0x77 EAN 13 E0 d 0x64 EAN 8 E4 D 0x44 EAN UCC Composite em 0 3 y 0x79 EAN 13 with Extended Coupon Code E3 d 0x64 ID tag UPU 4 State X0 N 0x4E Interleaved 2 of 5 lm 0 1 3 e 0x65 Japanese Post X0 J 0x4A KIX Net...

Page 134: ... 0x4F MICR E 13B1 ZE O 0x4F U S Currency Font1 o3 O 0x4F SEMI Font1 o3 O 0x4F PDF417 Lm 0 2 r 0x72 Planet Code X0 L 0x4C Plessey Code P0 n 0x6E PosiCode pm 0 1 2 W 0x57 Postnet X0 P 0x50 QR Micro QR Code Qm 0 6 s 0x73 GS1 DataBar GS1 DataBar Limited GS1 DataBar Expanded em 0 y 0x79 Straight 2 of 5 IATA two bar start stop Rm 0 1 3 f 0x66 TCIF Linked Code 39 TLC39 L2 T 0x54 Telepen Bm 0 1 2 4 t 0x74...

Page 135: ... DC1 60 3C 103 67 g 146 92 189 BD 232 E8 è 18 12 DC2 61 3D 104 68 h 147 93 190 BE 233 E9 é 19 13 DC3 62 3E 105 69 i 148 94 191 BF 234 EA ê 20 14 DC4 63 3F 106 6A j 149 95 192 C0 À 235 EB ë 21 15 NAK 64 40 107 6B k 150 96 193 C1 Á 236 EC ì 22 16 SYN 65 41 A 108 6C l 151 97 194 C2 Â 237 ED í 23 17 ETB 66 42 B 109 6D m 152 98 195 C3 Ã 238 EE î 24 18 CAN 67 43 C 110 6E n 153 99 196 C4 Ä 239 EF ï 25 19...

Page 136: ...lable for Code 39 Code 93 and Code 128 Code Page Standard Description 1 CP ISO646 2 Default ISO 2022 Automatic National Replacement Characters 3 CP Binary 82 ISO 2022 11 Swe Swedish Replacement Characters 83 ISO 2022 69 Fra French Belgian Replacement Characters 81 ISO 2022 25 Fra French Belgian Replacement Characters 84 ISO 2022 11 Ger German Replacement Characters 85 ISO 2022 11 Ita Italian Repla...

Page 137: ......

Page 138: ......

Page 139: ......

Page 140: ... A 0 123456 7890 Interleaved 2 of 5 Code 128 EAN 13 Code 39 Codabar 1234567890 Code 128 9 780330 290951 BC321 A13579B Code 93 123456 9 Straight 2 of 5 Industrial 123456 6543210 Matrix 2 of 5 GS1 DataBar 01 00123456789012 ...

Page 141: ...062315014880T PDF417 Postnet Code 49 Car Registration Zip Code 1234567890 Data Matrix QR Code Test Symbol Numbers 4 CB 4 State Customer Barcode 01 234 567094 987654321 01234567891 Micro PDF417 Test Message Aztec Package Label MaxiCode Test Message ...

Page 142: ...OCR Programming Chart a e d g c h t l r ...

Page 143: ...OCR Programming Chart T D A O Save Discard ...

Page 144: ...Programming Chart A C B F E D 1 0 2 ...

Page 145: ...Programming Chart Note If you make an error while scanning the letters or digits before scanning Save scan Discard scan the correct letters or digits and Save again 8 9 Save Discard 6 7 5 4 3 ...

Page 146: ... Honeywell 700 Visions Drive P O Box 208 Skaneateles Falls NY 13153 0208 4800dr BCG Rev B 4 09 ...

Reviews: