Table 7.5. Troubleshooting.
Symptom
Possible cause
Test
Solution
Display dark/
No function
Missing input power
See Table 4.4
Check the input power
source.
Missing or open fuses or
circuit breaker tripped
See open fuses and
tripped circuit breaker in
this table for possible
causes.
Follow the
recommendations
provided.
No power to the LCP
Check the LCP cable for
proper connection or
damage.
Replace the faulty LCP or
connection cable.
Shortcut on control
voltage (terminal 12 or
50) or at control terminals
Check the 24 V control
voltage supply for
terminals 12/13 to 20-39
or 10 V supply for
terminals 50 to 55.
Wire the terminals
properly.
Incompatible LCP
Use only LCP 101 or LCP
102.
Wrong contrast setting
Press [Status] + [
]/[
]
to adjust the contrast.
Display (LCP) is defective
Test using a different
LCP.
Replace the faulty LCP or
connection cable.
Internal voltage supply
fault or SMPS is defective
Contact supplier.
Intermittent
display
Overloaded power supply
(SMPS) due to improper
control wiring or a fault
within the adjustable
frequency drive
To rule out a problem in
the control wiring,
disconnect all control
wiring by removing the
terminal blocks.
If the display stays lit,
then the problem is in the
control wiring. Check the
wiring for short circuits or
incorrect connections. If
the display continues to
cut out, follow the
procedure for display
dark.
Summary of Contents for 3G SmartVFD HVFD3D2A0020
Page 1: ...3G SmartVFD Installation and User Guide ...
Page 5: ...iv 31 00559 01 ...
Page 15: ...10 31 00559 01 ...
Page 19: ...14 31 00559 01 ...
Page 23: ...18 31 00559 01 ...
Page 53: ...48 31 00559 01 ...
Page 83: ...78 31 00559 01 ...
Page 109: ...103 31 00559 01 ...
Page 125: ...119 31 00559 01 ...
Page 126: ......
Page 127: ... Honeywell 715 Peachtree Street NE Atlanta GA 30308 buildings honeywell com 31 00559 01 08 22 ...