CHAPTER
8
31-00559-01
78
SPECIFICATIONS
8 Specifications
8.1 Electrical Data
Table 8.1. Line Power Supply 3x200–240 V AC.
1) Efficiency measured at nominal current. For energy efficiency class see Chapter 8.4 Ambient
Conditions.
2) Applies for dimensioning of frequency converter cooling. If the switching frequency is higher than the
default setting, the power losses may increase. LCP and typical control card power consumptions are in-
cluded.
Type Designation, HVFD3D…
3A0015
2A0020
3A0030
3A0050
Typical Shaft Output [HP] at 208 V
1.5
2.0
2.9
4.9
Typical Shaft Output [kW]
1.1
1.5
2.2
3.7
Enclosure Size
IP21/NEMA 1
A2
A2
A2
A3
IP55/NEMA 12
A5
A5
A5
A5
Output Current
Continuous (3x200–240 V) [A]
6.6
7.5
10.6
16.7
Intermittent (3x200–240 V) [A]
7.3
8.3
11.7
18.4
Continuous kVA (208 V AC) [kVA]
2.38
2.70
3.82
6.00
Max. Input Current
Continuous (3x200–240 V) [A]
5.9
6.8
9.5
15.0
Intermittent (3x200–240 V) [A]
6.5
7.5
10.5
16.5
Additional Specifications
Estimated power loss at rated max. load [W]
2
)
63
82
116
185
IP21 max. cable cross-section (line power, motor,
brake and load sharing) [AWG/(mm
2
)]
12 (4)
IP55 max. cable cross-section (line power, motor,
brake and load sharing) [AWG/(mm
2
)]
12 (4)
Efficiency
1
0.96
0.96
0.96
0.96
Summary of Contents for 3G SmartVFD HVFD3D2A0020
Page 1: ...3G SmartVFD Installation and User Guide ...
Page 5: ...iv 31 00559 01 ...
Page 15: ...10 31 00559 01 ...
Page 19: ...14 31 00559 01 ...
Page 23: ...18 31 00559 01 ...
Page 53: ...48 31 00559 01 ...
Page 83: ...78 31 00559 01 ...
Page 109: ...103 31 00559 01 ...
Page 125: ...119 31 00559 01 ...
Page 126: ......
Page 127: ... Honeywell 715 Peachtree Street NE Atlanta GA 30308 buildings honeywell com 31 00559 01 08 22 ...