89
31-00559-01
8.1.4 Line Power Supply 3 x 525–690 V AC
Table 8.12. Line Power Supply 3x525–690 V AC - Normal overload 110% for 1 minute,
150 to 200 HP.
1) Typical power loss is at normal conditions and expected to be within ±15% (tolerance relates to variety
in voltage and cable conditions). These values are based on a typical motor efficiency (IE/IE3 border
line). Lower efficiency motors add to the power loss in the drive. Applies to dimensioning of drive cooling.
If the switching frequency is higher than the default setting, the power losses can increase. LCP and typ-
ical control card power consumptions are included.Options and customer load can add up to 30 W to the
losses, though usually a fully loaded control card and options for slots A and B each add only 4 W.
2) Measured using 5 m (16.4 ft) shielded motor cables at rated load and rated frequency. Efficiency mea-
sured at nominal current. For energy efficiency class, see Chapter 8.4 Ambient Conditions.
Type Designation, HVFD3D…
3D1500
3D2000
Typical shaft output at 575 V [hp]
150
200
Typical shaft output at 525 V [kW]
110
132
Typical shaft output at 690 V [kW]
132
160
Enclosure Size
IP21/NEMA 1
D1
D1
IP54/NEMA 12
D1
D1
Output Current
Continuous (3x525 V) [A]
162
201
Intermittent (3x525 V) [A]
178
221
Continuous (3x575/690 V) [A]
155
192
Intermittent (3x575/690 V) [A]
171
211
Continuous kVA (525 V AC) [kVA]
147
183
Continuous kVA (575 V AC) [kVA]
154
191
Continuous kVA (690 V AC) [kVA]
185
230
Maximum Input Current
Continuous (3x525 V) [A]
156
193
Continuous (3x575/690 V) [A]
149
185
Additional Specifications
Estimated power loss at 575 V [W]
1, 2
2101
2649
Estimated power loss at 690 V [W]
1, 2
2167
2740
Mains, motor, brake, and load share [AVG/(mm
2
)]
2x3/0
(2x95)
2x3/0
(2x95)
Efficiency
2
0.98
0.98
Summary of Contents for 3G SmartVFD HVFD3D2A0020
Page 1: ...3G SmartVFD Installation and User Guide ...
Page 5: ...iv 31 00559 01 ...
Page 15: ...10 31 00559 01 ...
Page 19: ...14 31 00559 01 ...
Page 23: ...18 31 00559 01 ...
Page 53: ...48 31 00559 01 ...
Page 83: ...78 31 00559 01 ...
Page 109: ...103 31 00559 01 ...
Page 125: ...119 31 00559 01 ...
Page 126: ......
Page 127: ... Honeywell 715 Peachtree Street NE Atlanta GA 30308 buildings honeywell com 31 00559 01 08 22 ...