![Honda HondaJet HA-420 Pilots Operating Manual Download Page 69](http://html1.mh-extra.com/html/honda/hondajet-ha-420/hondajet-ha-420_pilots-operating-manual_2158199069.webp)
Honda Aircraft Company
HA-420
SYSTEMS
POM
DESCRIPTION
HJ1-29000-005-001
October 30, 2016
1-53
Annunciator Panel
An Annunciator Panel is located on the glareshield above each of the
PFD displays in the primary field of view.
Figure 1-33. Annunciator Panel
The DISPLAY REVERSION switch is an alternate-action push-button
switch. The normal state is dark and the non-normal state is amber REV.
The CHIME switch is a momentary-action push-button switch. The
normal state is dark and the non-normal state is amber MUTE. The two
CHIME switches are synchronized, and pushing either will toggle the
mode of both switches.
The master WARNING / CAUTION switch is a momentary-action push-
button switch. The normal state is dark and the non-normal state is amber
CAUTION or RED WARNING. The two WARNING/CAUTION
switches are synchronized; pushing either (when illuminated) will
extinguish the light in both switches.
The BARO SET is a rotary control with multiple detents (“clicks”). The
knob also has a momentary type push action.
FOR TRAINING PURPOSES ONLY