1-161
Automatic wing anti-ice activation is inhibited in the following cases:
•
On the ground
•
During the first 30 seconds after liftoff
•
At or above FL340
•
In the Keep Out zone
Figure 1-77. Wing Anti-Ice Keep Out Zone
If the WING FLOW switch is selected to FROM L or FROM R, the
WAIV on the opposite (“to”) side is commanded closed and the WAIXV
is commanded open. In the NORM position, the system will
automatically command the WAIXV open if a loss of bleed flow is
detected on either side.