15
CONTROLS & FEATURES
Eco-Throttle
Switch
Parallel Operation Outlets
ON:
OFF:
O
O
F
F
F
F
PARALLEL OPERATION OUTLETS
O
O
N
N
ECO-THROTTLE SWITCH
TM
TM
The Eco-Throttle
system automatically reduces engine speed when
loads are turned off or disconnected. When appliances are turned on
or reconnected, the engine returns to the proper speed to power the
electrical load.
If high electrical loads are connected simultaneously, turn the
Eco-Throttle switch to the OFF position to reduce voltage changes.
Recommended to minimize fuel consumption and further
reduce noise levels when less than a full load is applied to the
generator.
The Eco-Throttle system does not operate.
When using the DC output, turn the Eco-Throttle switch to the
OFF position.
These outlets are used for connecting two EU1000i generators for
parallel operation (see page
). A Honda approved parallel operation
cables (optional equipment) is required for parallel operation. This
cable can be purchased from an authorized Honda generator dealer.
10/03/11 12:56:44 31ZT3620_016