Homa HRZ Original Instruction Manual Download Page 25

EngliSH | 25

Laying the motor connection lead

The cable holders described here are not part of 

standard supply of the recirculation pump. 

Lay cable holder (2) with rubber sleeve (3) just above 
the recirculation pump around the connecting cable and 
screw it on with a hexagon bolt. Hook karabiners (4) and 
steel cable or chain (5) into the cable holder (2). 

The connection cables must always be laid so that 

they cannot find their way into the propeller or be-

come subject to tension. Mount second cable holder 

directly below the shackle (6) in the same way. Mount 

all other cable holders in the same way, so that the 

distances between them increase corresponding 

with the increasing distance from the recirculation 

pump. Hang connection cable from cable hook with 

strain relief.

5.3. Commissioning

The recirculation pump must not run dry, since the 

engine can overheat during a dry run, leading to 

damage. 

The recirculation pump may only be put into opera-

tion if the checks have been made according to 

Chapter 5 and it has been ensured that there are no 

obstructions in the stirring tank. In addition, it must 

be ensured that the recirculation pump is submerged 

up to at least half of the propeller diameter. 

Furthermore, it must be ensured that no personnel can ac-
cidentally fall into the pool. The protective devices provid-
ed for this purpose (covers, railings, etc.) must be mount-
ed. During prolonged shutdown of the recirculation pump, 
the housing outside the stirring basin should be cleaned 
of dried mix medium before recommissioning. Not doing 
so may result in deterioration of the natural cooling during 
operation.

5.4. Electrics 

The selection and laying of electrical lines and the con-
nection of the motor must comply with the appropriate 
local and VDE regulations. The motor must be protected 
with a motor protection switch. Have the motor connect-
ed in accordance with the wiring diagram. Pay attention 
to the direction of rotation! If the direction of rotation is 
incorrect, the machine will not perform as stated and un-
der unfavourable circumstances, thus it may be damaged. 
Check the operating voltage and ensure a a uniform cur-
rent consumption during all phases in accordance with the 
machine data sheet. Make sure that all temperature sen-
sors and monitoring devices are connected and checked 
for proper function.

Danger due to electric current! Improper use of elec-

tricity can be fatal! All pumps with free cable ends 

must be connected by a qualified electrician.

5.5. Motor protection

The minimum requirement is a thermal relay / motor pro-
tection switch with temperature compensation, differen-
tial triggering and restart lockout in accordance with VDE 
0660 or the corresponding national regulations. If the 
machines are connected to grids in which interference 
frequently occurs, we recommend the additional instal-
lation of protective devices (e.g. over-voltage, under-volt-
age or phase failure relays, lightning protection etc.). The 
machine must be connected in compliance with local and 
legal regulations.

5.6. Operation with static frequency converter

The following points are to be taken into account for oper-
ation with a frequency converter:

• 

The pump is suitable for operation with a frequency 
converter in accordance with DIN EN 60034-17

• 

Voltage spikes on the motor windings must be avoid-
ed and, if appropriate, provide suitable filters in the 
motor cable

• 

It should be ensured that the overall system is 
grounded properly

• 

Information from the frequency converter manufac-
turer must be complied with

• 

Shielded cable may be required in some circumstanc-
es for compliance with EMC guidelines

• 

The code of practice „Use of HOMA pumps with a 
frequency converter“ must be complied with

5.7. Start-up modes

Start-up modes with cables with free ends (without plugs)

Star-delta activation 

If the motor protection is installed in the line: Set the mo-
tor protection to 0.58 x rated current. The starting time in 
the star connection must not exceed 3s max.
If the motor protection is not installed in the line: Under 
full load, set the motor protection to the rated current.

Switching on with starter transformer / soft starting

Under full load, the motor protection should be set to the 
rated current. Under partial-load operation, it is recom-
mended that the motor protection be set 5% above the 
measured current at the operating point. 

Summary of Contents for HRZ

Page 1: ...Original Betriebsanleitung EN Original Instruction Manual NL Originele handleiding HRZ...

Page 2: ...rdermedien 06 3 Allgemeine Beschreibung 07 3 1 Verwendung 07 3 2 Einsatzarten 07 3 3 Aufbau 07 4 Verpackung Transport und Lagerung 09 4 1 Anlieferung 09 4 2 Transport 09 4 3 Lagerung 09 4 4 R ckliefe...

Page 3: ...ur Unfallverh tung Diese Betriebsanleitung muss dem Bedienpersonal jederzeit am Einsatzort des Produk tes verf gbar sein 1 3 Bestimmungsgem e Verwendung Die HOMA Produkte entsprechen den g ltigen Sich...

Page 4: ...m ig durchzuf hren und d rfen nur von qualifi zierten und autorisierten Personen durchgef hrt werden Wartungsarbeiten und jegliche Art von Reparaturarbeiten die nicht in dieser Betriebsanleitung aufge...

Page 5: ...auftretende St rung oder Un regelm igkeit sofort seinem Verantwortlichen zu melden Eine sofortige Stillsetzung durch den Bediener ist zwingend erforderlich wenn M ngel auftreten wel che die Sicherheit...

Page 6: ...stoffe k nnen sich an diesen Teilen sehr scharfe Kanten bilden Warnung vor drehenden Teilen Die drehenden Teile k nnen Gliedma en quetschen und abschneiden W hrend des Betriebes nie in das R hrwerk od...

Page 7: ...m Volumenstrom bei kleiner F rderh he bis max 1 5 Trockensubstanzgehalt Einsatzgebiete sind unter anderem das F rdern von Belebtschlamm aus Nitrifikation in Denitrifikation Naturbadeteiche Wasserbahne...

Page 8: ...tung Zwei Radialwellendich tringe au en Siliziumkarbid Siliziumkarbid innen Lagerung zwei Kegelrollenlager 3 3 4 berwachungseinrichtungen Das Aggregat ist mit verschiedenen berwachungs Si cherheitsein...

Page 9: ...bkni cken Besch digungen und Feuchtigkeitseintritt zu sch tzen Gefahr durch elektrischen Strom Durch besch digte Stromzuf hrungsleitungen droht Lebensgefahr Defekte Leitungen m ssen sofort vom qualifi...

Page 10: ...Es besteht Lebensgefahr Treffen Sie alle Sicherheitsvorkehrungen um dies zu verhindern Installation des F hrungsrohres Die Druckleitung sowie der erforderliche Flansch DIN 2631 PN6 ist bauseits vor d...

Page 11: ...un gen sowie beim Anschluss des Motors sind die entspre chenden rtlichen und VDE Vorschriften einzuhalten Der Motor muss durch einen Motorschutzschalter gesch tzt werden Lassen Sie den Motor gem dem S...

Page 12: ...dingun gen Bei aggressiven und oder abrasiven F rdermedien muss R cksprache mit dem Hersteller gehalten werden da sich in diesen F llen der Zeitraum verk rzen kann Folgende Punkte sind zu beachten Die...

Page 13: ...n Diese Liste ist der Berufsgenossen schaft den Technischen berwachungsvereinen sowie dem Hersteller der Anlage bzw des R hrwerkes auf Ver langen vorzuzeigen Der volle Garantieanspruch setzt die j hrl...

Page 14: ...einem festen Untergrund vertikal abstellen und gegen Umfallen sichern Bei Pumpen muss der Druck und Sauganschluss mit geeigneten Hilfsmitteln z B Folie verschlossen wer den Die elektrische Anschlussl...

Page 15: ...seinrichtungen sind dann mit dem Lastkabel ausgef hrt Aderbezeichnung Motor berwachungseinrichtung berwachungen in der Wicklung T1 T2 Temperaturbegrenzer 2 Schalter in Reihe T1 T3 Temperaturregler 2 S...

Page 16: ...neral description 21 3 1 Use 21 3 2 Types of use 21 3 3 Design 21 4 Package Transport Storage 23 4 1 Delivery 23 4 2 Transport 23 4 3 Storage 23 4 4 Returning to the supplier 23 5 Installation and com...

Page 17: ...ual must also be accessible to personnel at all times and also be made available where the product is used 1 3 Proper use The HOMA products comply with the valid safety regu lations and meet the deman...

Page 18: ...he product and or injure personnel 1 5 3 Maintenance The prescribed maintenance and inspection work should be carried out regularly This work may only be carried out by qualified trained and authorize...

Page 19: ...d or control devices Damage to critical parts Damage to electric installations cables and in sulation Tools and other objects should be kept in a place re served for them so that they can be found qui...

Page 20: ...fety and control devices Our products are equipped with various safety and con trol devices These include for example suction strainers thermo sensors sealed room monitor etc These devices must never...

Page 21: ...y Sn Type Prop F mm N Tmax C min 1 kg min 1 Motor kW Ins cl Hz A U U V P2 V kW Cos I A I P1 Made in Germany Do not open when non intrinsically safe circuits are energized 3 m 3 2 4 5 6 7 8 13 14 15 16...

Page 22: ...onnection the correct rotation direction of the propeller must be checked The propeller must rotate clockwise as seen from the motor If the rotation direction of the stirring propeller is incorrect tr...

Page 23: ...ore storage to prevent impurities The power supply cables should be protected against kinking damage and moisture Beware of electrical current Damaged power supply cables can cause fatal inju ry Defec...

Page 24: ...otwear may cause a fall Danger of death Follow all safety pre cautions in order to prevent this Installation of the guide tube The discharge line and the required flange DIN 2631 PN6 should be install...

Page 25: ...damaged Check the operating voltage and ensure a a uniform cur rent consumption during all phases in accordance with the machine data sheet Make sure that all temperature sen sors and monitoring devi...

Page 26: ...enance inspection and cleaning work on the machine and the system must be carried out with the greatest care by trained specialist personnel in a safe workplace The necessary personal protective equip...

Page 27: ...rer on request The full warranty claim requires the annual review of the recir culation pump by the manufacturer of the system or the recirculation pump 6 2 1 General Monthly or per every 500 hours of...

Page 28: ...inst frost Place it down vertically onto a firm foundation and secure it against falling Seal the intake and discharge ports of pumps with suitable material such as foil Support the electric connectin...

Page 29: ...ng devices are run from the power cable Cable identification Motor Monitoring system Monitoring in winding T1 T2 Temperature limiter 2 switches in series T1 T4 Temperature controller 2 switches in ser...

Page 30: ...emene beschrijving 35 3 1 Toepassing 35 3 2 Toepassingswijzen 35 3 3 Opbouw 35 4 Verpakking transport en opslag 37 4 1 Aanlevering 37 4 2 Transport 37 4 3 Opslag 37 4 4 Retourneren 38 5 Opstelling en...

Page 31: ...dt deze uit Deze handleiding moet altijd beschikbaar zijn voor het bedie ningspersoneel op de werkplek van het product 1 3 Beoogd gebruik De HOMA producten voldoen aan de geldende veilig heidsregels e...

Page 32: ...nsti ge schade aan het product en of tot ernstig letsel 1 5 3 Onderhoud De voorgeschreven onderhouds en inspectiewerkzaam heden moeten regelmatig worden uitgevoerd en mogen uitsluitend door gekwalific...

Page 33: ...g onmiddel lijk melden aan zijn leidinggevende Een onmiddellijke stilzetting door de bediener is dwin gend noodzakelijk wanneer er gebreken optreden die de veiligheid in gevaar brengen Hieronder valle...

Page 34: ...erantwoordelijk voor de nale ving van de voorschriften Tijdens het bedrijf draaien bepaalde onderdelen waaier propeller om de vloeistof te verpompen Door bepaalde bestanddelen kunnen er aan deze onder...

Page 35: ...eze vloeistoffen 3 Algemene beschrijving 3 1 Toepassing De recirculatiepompen zijn geschikt voor pomptoepassin gen met grote volumestroom bij kleine opvoerhoogte tot max 1 5 drogestofgehalte Toepassin...

Page 36: ...oefkogellagers 3 3 3 Overbrenging Algemene overbrengingsgegevens Type Planeetaandrijving Tandwielen gehard en geslepen Beschermingsklasse IP68 Asafdichting glijringafdichting Twee keerringen buiten Si...

Page 37: ...en schade bij transport en opslag uit Bij een regelmatige wisseling van locatie dient u de verpakking zorgvuldig te bewaren voor hergebruik 4 3 Opslag Nieuw geleverde producten zijn dusdanig behandeld...

Page 38: ...dat de elastomere delen en de coatings onderhevig zijn aan een natuurlijke verbrossing Wij adviseren deze bij een opslag van meer dan 6 maan den te controleren en indien nodig te vervangen Overleg hi...

Page 39: ...stigd dat deze niet in de propeller terecht kan ko men en niet onder spanning staat Na het laten zak ken van de recirculatiepomp moet de ketting of de staalkabel worden ontlast Aanleggen van de motora...

Page 40: ...aleven van de EMC richtlijnen Het informatieblad Toepassing van HOMA pompen op een frequentieomvormer moet in acht worden genomen 5 7 Inschakelwijzen Inschakelwijzen bij kabels met vrije uiteinden zon...

Page 41: ...de gereedschap en materi aal beschikbaar is Orde en reinheid garanderen veilig en probleemloos werken aan de machine Verwijder na de werkzaamheden gebruikt poetsmateriaal en gereedschap van de machine...

Page 42: ...t stroomnet Bij een tij delijke buitenbedrijfstelling moet de pomp compleet onder gedompeld blijven zodat deze beschermd is tegen vorst en ijs Er moet worden gegarandeerd dat de bedrijfsruimte en de v...

Page 43: ...n dan met de hijskabel uitgevoerd Aderaanduiding motor Bewakingscontrole Bewakingen in de wikkeling T1 T2 Temperatuurbegrenzer 2 schakelaars in serie T1 T4 Temperatuurregelaar 2 schakelaars in serie T...

Page 44: ...edingte Kontaminierung des Ger tes toxisch nein ja welche Stoffe tzend nein ja welche Stoffe mikrobiologisch nein ja welche Stoffe explosiv nein ja welche Stoffe radioaktiv nein ja welche Stoffe sonst...