2. Safety Warnings 

2.1. General Instructions 
Signs used to mark instructions in this manual 

Safety instructions in these operating instructions, 

which, if not observed, could cause a danger for persons 
are marked with the general symbol in accordance with 
DIN 4844-W 9. 

Warnings against electrical voltage are marked with 

the safety symbol in accordance with DIN 4844-W 8. 
 

2.2. General Safety Precautions

 

General regulations and guidelines not mentoined in the  
safety warnings retain their validity. 

These operating instructions contain basic instruc-

tions, which have to be adhered to during installation, op-
eration and maintenance. These operating instructions 
must be read from mechanic and the operator before in-
stallation and operation of the pump and have to be kept 
available at the operating place of the machine/unit at all 
times. Persons who are not familiar with the operating in-
structions shall not use this product. 

Children and adolescents under age 16 shall not use 
the pump and must keep away from the machine/unit  
while it is operational.

 

The working area has to be closed off expediently 

and must adhere to local workplace regulations. 

Always use personal safety equipment such as safety 

boots, rubber gloves, safety glasses and helmet. 

Make sure that the emergency exit from the workplace 

is not barricaded. 

To prevent suffocation and poisoning caused by ven-

omous gases, make sure that enough oxygen exists at the 
workplace. 

If you have to work with welding tools or electric tools, 

make sure that there is no explosion hazard. 

Immediately after repair or maintenance work, all 

safety and protection equipment must be reinstalled and 
placed in function again. 

The operator of the pump is responsible for third par-

ties within the work area. 

Never put a hand or finger into suction inlet or dis-

charge of the pump while the impeller is rotating. 

Persons are not permitted to stay in the pumping me-

dium during operation of the pump. 

All other rules and regulations and local codes cover-

ing health and safety must be observed. In accordance 
with product liability law, we point out that we shall not be 
liable for damages caused by the pump due to non-
observance of the instructions and guidelines set forth in 
the operating instructions. The same product liability are 
valid for accessories. 

3. Applications and Technical Description 

3.1. Applications 

If the pump is used for cleaning or maintenance of 

swimming pools, make sure that no persons stay in the 
swimming pool during operation of the pump and that the 
pump is self-assured by a 30 mA earth leakage circuit 
breaker.The pumps are designed for pumping waste water 
or effluent containing sludge or soft solids.  
The pumps are used for installations in public and private 
sector, trade and industry. 
The pumps must not be used for pumping of liquids con-
taining great quantities of abrasive solids, like sand or 
stones. Before the pumping of chemically aggressive liq-
uids, the resistance of the pump materials must be 
checked. 
The pumps may be used for both temporary or permanent 
installation. The installation for submerged installation can 
be free-standing on a base-stand or by means of an auto-
coupling guide rail system (see under 7.). 
For dry well installation of the pump in a separate sump all 
models are available with a motor jacket cooling. 
 
Special considerations must be taken when operating 
pumps with variable frequency drives (invertres). The in-
verter circuit design, horsepower required by pump, motor 
cooling syste, power cable length, operating voltage and 
anticipated turndown ratio must be fully evaluated during 
the design stage of the installation. As a minimum, prop-
erly sized load reactors and filters must be installed be-
tween the inverter and the pump to protect the pump mo-
tor from damaging voltage spikes. Warranty coverage will 
not be provided on any pump motor that is operated with a 
variable frequency drive, unless the load side of the in-
verter is properly isolated from the pump. 
 

3.2. Technical Data 

Discharge DN 

100 

Voltage 

400 V / 3 Ph 

Speed 2.900 

rpm 

Insulation class 

Motor protection 

IP 68 

Max. liquid temperature 

35°C, short term up to 60°C 

Cable type 

 

H 163 – H 165 

H07RN-F7G1,5 

H 172 – H 179 

H07RN-F10G4 

Noise level during operation,  
1,60 m from the ground 

 70d(B)A 

 

3.3. Operating Conditions 
Maximum liquid temperature:

 35°C, short term up to 

60°C. 

Density of pumped liquid:

 max. 1100 kg/m

3

 

Ph-value of pumped liquid:

 5 up to 11. 

Level of pumped liquid:

 The lowest level must always be 

above the top of the pump housing (volute). 

Operation:

 The motors are designed for continuous op-

eration (S1) with fully submerged motor, maximum 15 
starts per hour.  
 
Our standard warranty and maintenance regulations refer 
to intermittent operation. For reduced warranty periods 
and service intervals due to continuous operating condi-
tions please contact our service 
department. 

Summary of Contents for H 163 Series

Page 1: ...nstruction Manual Origineel Bedrijfinstrukties Original Manuel d instructions de montage HOMA Pumpenfabrik GmbH 02 2011 Industriestr 1 D 53819 Neunkirchen Seelscheid Baureihe Series S ries H 163 H 165...

Page 2: ...ite 34 Page 34 Pagina 35 Page 35 DEUTSCH ENGLISH NEDERLANDS FRAN AIS Elektroanschluss Electrical connection Aansluitdiagram Raccordement lectrique Bauma e Dimensions Bouwmaten Encombrements Ersatzteil...

Page 3: ...178 H 179 aufgrund ihrer Konzipierung und Bauart sowie in der von uns in Verkehr gebrachten Ausf hrung den einschl gigen grundlegenden Sicherheits und Gesundheitsanforderungen der EG Maschinenrichtli...

Page 4: ...kthaf tungsgesetz f r Sch den die durch unser Ger t verur sacht werden wenn die Hinweise und Vorschriften aus dieser Bedienungsanleitung nicht eingehalten werden nicht haften F r Zubeh rteile gelten d...

Page 5: ...sind als Zubeh r lieferbar s Schaltger te Programm Bei Verwendung anderer Schaltger te ist bei der Auslegung des Motorschutzschalters auf den Nenn strom des Motors zu achten siehe Typenschild Start A...

Page 6: ...ition von Kupplungsfu und oberer Rohrkonsole f r die F hrungsrohre in etwa festlegen ggf Senklot ver wenden Korrekte Einbauma e der Pumpe n berpr fen s Ma zeichnungen im Anhang Befestigungsl cher f r...

Page 7: ...sierten Fachwerkstatt durchgef hrt werden Umbau oder Ver nderungen an der Pumpe sind nur nach Ab sprache mit dem Hersteller zul ssig Es d rfen nur Origi nal HOMA Ersatzteile verwendet werden Wir weise...

Page 8: ...r von einer Elektro Fachkraft berpr fen und ausbessern lassen sofort aus Achtung Nicht wieder einschalten Sicherung durchgebrannt da falscher Typ Sicherung durch korrekten Typ ersetzen Laufrad durch V...

Page 9: ...ingen 03 31 740 40 70 0 74 31 95 83 24 Naumann Pumpen GmbH Co KG G Meier GmbH Am Wall 11 Gustav Schwab Str 16 14979 Gro beeren 72762 Reutlingen 03 37 01 52 50 0 71 21 26 90 0 HEKO Pumpen GmbH Pumpen Z...

Page 10: ...t in respect to their design and construction the following pump types in the form in which they are marketed by us conform to the relevant fundamental safety and health re quirements of the EC Machin...

Page 11: ...d Technical Description 3 1 Applications If the pump is used for cleaning or maintenance of swimming pools make sure that no persons stay in the swimming pool during operation of the pump and that the...

Page 12: ...s are marked U1 U2 V1 V2 and W1 W2 For star delta start the pump must be connected to an appropriate starter box see page 21 If a motor wich is prepared for star delta start as de scribed above is sup...

Page 13: ...top of the guide rails and fasten it to the pit cover Make sure that the guide rails do not have any axial play as this would cause noise during pump operation Clean out debris from the pit before low...

Page 14: ...ry 1 000 operat ing hours For long and trouble free operation of the pump following points should be checked regularly Nominal current A Check with amp meter Pump parts and impeller Check for possible...

Page 15: ...f thermal relay in mo tor starter Set the relay in accordance with the specifications on the pump label Increased current consumption due to large voltage drop Measure the volt age between two motor p...

Page 16: ...7 H 178 H 179 Op grond van hun concipi ring en bouwwijze als ook in de door ons in verkeer gebrachte uitvoering aan de desbetreffende fundamentele veiligheids en gezondheidseisen van de EG machinerich...

Page 17: ...sprakelijk zijn voor schade welke door onze machines veroorzaakt worden wanneer de aanwij zingen en voorschriften uit deze gebruiksaanwijzing niet in acht genomen worden Voor toebehoren gelden dezelfd...

Page 18: ...n met een temperatuurvoeler set in de mo torwikkeling uitgerust welke de motor bij verhitting van de wikkeling uitschakelt Bij pompen in normale uitvoering worden de aansluitingen van de temperatuurvo...

Page 19: ...fieldich ting afdichting tegen koppelingsvoet vast in de uitspa ring van de tegenkoppeling gemonteerd is zodat het uit vallen van de dichting bij het uithalen van de pomp uit gesloten is Ketting aan d...

Page 20: ...nspecteer de pomp vaker als de gepompte vloeistof modderig of zanderig is of bij conti nubedrijf Bij nieuwe pompen of na plaatsing van een nieuwe asaf dichting dient men het oliepijl na 1 bedrijfsweek...

Page 21: ...gingschak elaar te laag ingesteld Instelling volgens de gegevens op de pomp typeplaat in acht nehmen Verhoogde stroomopname op grond van spanningsverlies Spanning tussen twee fasen meten Tolerantie 10...

Page 22: ...GmbH Industriestrasse 1 D 53819 Neunkirchen Seelscheid certifions que les pompes sp cifi es ci dessous H 163 H 165 H 172 H 175 H 176 H 177 H 178 H 179 correspondent aux exigences en mati re d hygi ne...

Page 23: ...le nettoyage entretien d une piscine s assurer que personne ne se trouve dans le liquide refoul et que les pompes sont aliment es par un dispositif de protection diff rentielle d une sensibilit au pl...

Page 24: ...commande s par de la gamme HOMA En cas d utilisation d autres appareillages lectriques assurez vous que le relais thermique tient compte du courant nominal du moteur lors du choix du disjoncteur voir...

Page 25: ...Mettre le pied d assise niveau par rapport au sol du puits Les barres de guidage doivent tre en position parfaitement verticale A l aide de chevilles pour charges lourdes fixer le pied au sol Veiller...

Page 26: ...essionnaire autoris Toute transformation ou modification de la pompe n cessite l accord pr alable du constructeur Seules les pi ces de rechange d origine doivent tre utilis es Il est rappel que confor...

Page 27: ...diate ment Pr caution Ne pas remettre la pompe en marche D faut d alimentation court circuit la terre par le c ble ou les enroulements moteur Les fusibles ont grill il s agit d un mauvais type de fusi...

Page 28: ...ammer Oil chamber seal conditions sensor Dichtingsbewaking Sonde d humidit de la chambre huile Abb 2 Fig 2 Netzanschluss Stern Dreieck Starter connection Start Delta Start Netaansluiting Ster Driehoek...

Page 29: ...stallation with ring base stand Natte opstelling met bodemring Installation portable sur tr pied H 163 H 165 H 163 H 179 Station re Nassaufstellung mit Kupplungssystem Permanent wet well installation...

Page 30: ...30 Station re Trockenaufstellung vertikal Permanent dry well installation vertical Droge opstelling vertikaal Installation fosse s che verticale H 163 H 165 H 172 H 179...

Page 31: ...Nr Bezeichnung Menge Lieferanschrift Unterschrift Firmenstempel 14 Order Sheet for Spare Parts To HOMA Pumpenfabrik GmbH D 53819 Neunkirchen Seelscheid Fax 49 22 47 7 02 44 Pump type see pump label Y...

Page 32: ...everadres handtekening firmastempel 14 Formulaire de commande de pi ces de rechange A HOMA Pumpenfabrik GmbH Industriestrasse 1 D 53819 Neunkirchen Seelscheid Fax 49 2247 70244 Type de pompe voir plaq...

Page 33: ...bung 999 xx Ersatzteile f r Schaltge r t 722 Anschlussstutzen 15 Spare part list and drawings 15 1 Spare part list ATTENTION The following list contains parts that do not correspond to every pump typ...

Page 34: ...peling 999 xx Onderdelen voor scha kelkast 722 Aansluiting 15 Liste de pi ces d tach es et plans 15 1 Liste de pi ces d tach es ATTENTION La liste ci dessous contient des pi ces qui ne sont pas pr sen...

Page 35: ...35 15 2 Ersatzteilzeichnung Spare part drawings Onderdelentekening Plans des pi ces d tch es H 163 H 165 H 163 Ex H 165 Ex H 163 U H 165 U H 163 U Ex H 165 U Ex...

Page 36: ...36 H 172 H 179 H 172 Ex H 179 Ex H 172 U H 179 U H 172 U Ex H 179 U Ex...

Page 37: ...xisch nein ja welche Stoffe _____________________ tzend nein ja welche Stoffe _____________________ mikrobiologisch nein ja welche Stoffe _____________________ explosiv nein ja welche Stoffe _________...

Page 38: ...______________ corrosive no yes which substance __________________ microbiological no yes which substance __________________ explosive no yes which substance __________________ radioactive no yes whic...

Page 39: ...37...

Page 40: ...38...

Reviews: