30
ELECTRICAL CHARACTERISTICS
Electrical Outputs
POWER SUPPLY
Mains supply: This unit runs off a 240 volt 50 hertz single phase outlet.
The controller draws 30 watt at 240 VAC.
The internal transformer reduces the 240 VAC to an extra low voltage supply of 24
VAC. The internal transformer is fully compliant with AS/NZS 61558-2-6 and has
been independently tested and judged to comply.
This unit has a 1.25AMP low energy, high efficient toroidal transformer for long life
performance.
ELECTRICAL POWER SUPPLY: Input 24 volts 50/60Hz
ELECTRICAL OUTPUTS: Maximum of 1.0 amp
To solenoid valves:
24 vac 50/60Hz 0.75 amps max
Note: up to 2 valves per station on the inbuilt model
To the master valve/pump start:
24 vac 0.25 amps max
Note: Transformer and fuse capacity must be compatible with output
requirements
OVERLOAD PROTECTION:
Standard 20mm M-205 1 amp fast blow glass fuse, protects against power surges
and electronic fuse rated to 1AMP protects against field faults. Faulty station skip
function.
POWER FAILURE:
The controller has permanent memory and real time clock, so the data is always
backed up even with the absence of all power. The unit is factory fitted with a 3V
CR2032 Lithium Battery with up to 10 years memory backup.
The 9V Alkaine battery maintains the display during power outs, and can be used for
remote programming where no AC power is available.