13
MANUAL OPERATIONS
Run a Single Station
The maximum run time for a station is 12 hours 59 minutes. To manually run a single
station once, turn the dial to the “Run Single Station /
System Test” position.
The display will show:
The default run time for a single station is 10 minutes.
Advance to the selected station by pressing
as many
times as required, and then press
to adjust the run time with
and
.
The controller will start running the selected station and the run time will decrement in
the display.
If there is a pump or master valve connected, “PUMP A” will be shown in the display.
Indicating that the pump/master is running. As soon as the single station run time has
elapsed, the unit will revert back to automatic mode. This means that if you forget to
turn the dial back to the “Auto” position, the controller will still run its automatic starts,
as scheduled. To turn the station off, change the position of the main dial, to “OFF”.
HINT: If you wish to alter the default value from 10 mins to some other value and
set this as the new default time. Turn the dial to “Run Single Station” press the
button followed by
.
Then alter the run time using the
or
buttons.
Once the new default time is set press the
button again, and the new default will
now always appear when you select a “Run A Single Station”.
System Test Feature
When the dial is in the “Run Single Station” position, press
button to show the
current AMPs for the selected station. As this controller has an electronic fuse (set
at 1.0AMPs), this is an important feature to show how much current each station is
drawing. If the current AMPs are higher than 1.0AMPs the electronic fuse will turn the
station “Off”. This usually means that there is a fault with the solenoid coil or a short in
the wiring. This fault needs to be fixed as the controller will skip the faulty station in the
“AUTO” run mode and no watering will occur in that area of the garden.
The display will also show the faulty station number and beep until midnight.
Press
to return to the station that you are testing. Each station can be tested by
pressing
and then
.