29
SUGGESTION
Check wiring and swap faulty station
wire’s on the controller terminal
block with known working stations.
If the same outputs are still locked
on, return panel to supplier or
manufacturer.
Electrician to check voltage on relay
or contactor.
Return panel to supplier or
manufacturer.
Slide switch on front panel to the ON
position, test all wiring and make sure
the sensor is a normally closed type.
Check programming to make sure
sensor is enabled.
Check programming, using the
manual as a reference and correct
mistakes.
SYMPTOM
More than one
station coming
on at once
Pump start
chattering
Display cracked
or missing
segments
Sensor input
not working
Pump not
working on a
specific station
or program
POSSIBLE CAUSE
Possible faulty driver triac
Faulty relay or pump
contactor
Display damaged during
transportation
Sensor enable switch in
the OFF position or faulty
wiring
Programming error with
pump enable routine
FAULT FINDING GUIDE