Water system problems and leaks usually fall into two categories: system
problems and problems caused by improper use or lack of attention. These
problems usually stem from improper winterizing, poor maintenance, road
vibration and campsite water pressure variations. Check all plumbing connec-
tions for leaks at least once a year. If the water pump runs when a faucet is not
open, check for a water leak. If a water line or fitting is leaking try to tighten
the fitting. If the leak has not stopped use the water manifold key to shut-off
the water supply valve. Have the leak repaired before returning the supply line
to service.
NOTE: A small water leak can cause severe water damage.
Shut-off the water supply and have the leak repaired.
Disinfecting water system with chlorine bleach (superchlorination) protects
you and your family from bacteriological or viral contamination from any
common water source.
You should disinfect the water system:
• If your motorhome is new.
• If your motorhome has not been used in a long time.
• Every
three
months.
NOTE: An independently operated water pump with garden
hose connections and a container to hold prepared solution
may be desired to perform this task. The gravity fill may
also be used to perform the task. Remove cap off the gravity
fill. Add the solution to the fresh water tank. When finished,
secure the gravity fill cap.
CAUTION: Do not use vinegar or chlorine bleach to disin-
fect water system on units using Hyrdo - Hot Heating
Systems. Vinegar will deteriorate copper tubing.
Use following procedure to disinfect water system:
• Remove the filter elements from the filters and reassemble the
filters without the elements (see "Filter").
• Prepare a chlorine bleach solution using 1 gallon water and 1/4
cup of chlorine bleach. Use 1 gallon of solution for every 15
gallons of tank capacity. Example: Add 2-2/3 gallons solution to
a 40 gallon tank. Add 4-2/3 gallons solution to a 70 gallon tank.
Add 6-2/3 gallons to 100 gallon tank. This mixture puts a 50
ppm (parts per million) disinfecting solution in the water sys-
tem. This concentration will act as a quick-kill dosage for harm-
ful bacteria, viruses and slime-forming organisms.
Concentrations higher than 50 ppm may damage the water lines
Water Systems
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
I M P E R I A L
6 • 1 5 2
WATER SYSTEM -
Troubleshooting
Summary of Contents for imperial 2001
Page 1: ......
Page 3: ...FOLD FOLD...
Page 7: ......
Page 23: ......
Page 63: ...Driving Safety IMPERIAL 2 6 3 NOTE...
Page 65: ......
Page 90: ...Care Maintenance SIGNATURE 3 9 0...
Page 119: ......
Page 145: ......
Page 163: ...Water Systems IMPERIAL 6 1 6 3 N O T E S...
Page 165: ......
Page 175: ......
Page 176: ......
Page 214: ......
Page 244: ......
Page 292: ...Chassis Information IMPERIAL 1 0 2 9 2 Date Mileage Dealer Address Service Remarks CHASSIS LOG...
Page 293: ...Chassis Information IMPERIAL 1 0 2 9 3 Date Mileage Dealer Address Service Remarks CHASSIS LOG...
Page 294: ...Chassis Information IMPERIAL 1 0 2 9 4 Date Mileage Dealer Address Service Remarks CHASSIS LOG...
Page 295: ...Chassis Information IMPERIAL 1 0 2 9 5 Date Mileage Dealer Address Service Remarks CHASSIS LOG...